Q5H9V36*K*AAA*
QuietComfort 19 SEER2 VS HP
450 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 450 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 450 / 450 |
| EER2 · BTU/Wh | 10.5–13.5 | 450 / 450 |
| HSPF2 · BTU/Wh | 7.8–9 | 450 / 450 |
| Cooling capacity · BTU/h | 33,400–37,600 | 450 / 450 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,800–37,400 | 450 / 450 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,200–37,600 | 450 / 450 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–26,600 | 450 / 450 |
| COP at 5°F / −15°C | 1.9–2.18 | 450 / 450 |
| Equipment / loop type | HP - Split System | 450 / 450 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 450 / 450 |
| Compressor staging | Continuously variable | 450 / 450 |
| Connected capability | No | 450 / 450 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
QFVA5D4821X*Cold climate designationAHRI reference: 218695530 | 18.00 | 9.00 | 25400 | 2.00 | EPA 4683297 → |
FTMA5B48L0C*Cold climate designationAHRI reference: 218008861 | 17.00 | 9.00 | 25000 | 2.12 | EPA 4566840 → |
QFVA5D3617X*Cold climate designationAHRI reference: 218695514 | 17.00 | 9.00 | 25400 | 2.00 | EPA 4683313 → |
EVD5X38M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217912783 | 16.50 | 9.00 | 26000 | 2.12 | EPA 4529900 → |
EVM5X43M21A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 217909579 | 16.50 | 8.50 | 25000 | 2.05 | EPA 4532870 → |
EVM5X49M21A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 217952531 | 16.50 | 9.00 | 26000 | 2.12 | EPA 4563468 → |
EVM5X49M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217910937 | 16.00 | 9.00 | 26200 | 2.14 | EPA 4529881 → |
EVD5X38M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 217912768 | 16.00 | 9.00 | 26000 | 2.14 | EPA 4529886 → |
EVM5X49M21A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217910892 | 16.00 | 9.00 | 26400 | 2.12 | EPA 4529935 → |
EVM5X49M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217910907 | 16.00 | 9.00 | 26200 | 2.14 | EPA 4529951 → |
EVD5X38M17A*+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 217912813 | 16.00 | 9.00 | 26400 | 2.12 | EPA 4530013 → |
EVD5X38M17A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217912843 | 16.00 | 9.00 | 26200 | 2.12 | EPA 4530019 → |
EVD5X48M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 217914599 | 16.00 | 9.00 | 26200 | 2.12 | EPA 4530227 → |
EVM5X49M21A*+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 217910998 | 16.00 | 8.50 | 26200 | 2.00 | EPA 4530234 → |
EVM5X43M21A*+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 217909775 | 16.00 | 8.50 | 25200 | 2.06 | EPA 4530260 → |
EVM5X43M21A*+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 217909790 | 16.00 | 8.50 | 25000 | 2.05 | EPA 4530275 → |
EVM5X43M21A*+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 217909805 | 16.00 | 8.50 | 25200 | 2.05 | EPA 4530290 → |
EVM5X43M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217909910 | 16.00 | 8.50 | 25000 | 2.05 | EPA 4530496 → |
EVM5X43M21A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 217909880 | 16.00 | 8.50 | 24800 | 2.05 | EPA 4530512 → |
EVM5X43M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 217909895 | 16.00 | 8.50 | 24800 | 2.05 | EPA 4530526 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →