Q5H9V24*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 9
1,093 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,093 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,093 / 1,093 |
| EER2 · BTU/Wh | 11.5–14 | 1,093 / 1,093 |
| HSPF2 · BTU/Wh | 8–10 | 1,093 / 1,093 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,093 / 1,093 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,093 / 1,093 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,093 / 1,093 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,093 / 1,093 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,093 / 1,093 |
| Equipment / loop type | HP - Split System | 1,093 / 1,093 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,093 / 1,093 |
| Compressor staging | Continuously variable | 1,093 / 1,093 |
| Connected capability | No | 1,093 / 1,093 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X32M17A*+ furnace: OMV112K14ACold climate designationAHRI reference: 217938132 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4551702 → |
EVD5X31M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 217940949 | 19.00 | 8.50 | 21600 | 1.92 | EPA 4551718 → |
EVD5X31M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217940964 | 19.00 | 8.50 | 21800 | 1.92 | EPA 4551733 → |
EVM5X36M17A*+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 217938359 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4551746 → |
EVD5X31M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217940979 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4551803 → |
EVD5X31M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 217940994 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4551819 → |
EVD5X25M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217939978 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4551870 → |
EVM5X36M17A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 217938677 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4551982 → |
EVM5X36M17A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217938312 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4552002 → |
EVM5X36M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 217938327 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4552017 → |
EVD5X36M21A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 217942725 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4552163 → |
EVD5X36M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 217941631 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4552201 → |
EVD5X37M21A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217942980 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4552237 → |
EVD5X37M21A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 217942995 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4552240 → |
EVD5X37M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217943131 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4552254 → |
EVD5X37M21A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 217943146 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4552265 → |
EVD5X30M17A*+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 217940721 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4552285 → |
EVD5X30M17A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 217940751 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4552314 → |
EVM5X25M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 217936149 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4552361 → |
EVD5X36M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 217942755 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4552499 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.