Q5H9V24*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 11
1,093 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,093 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,093 / 1,093 |
| EER2 · BTU/Wh | 11.5–14 | 1,093 / 1,093 |
| HSPF2 · BTU/Wh | 8–10 | 1,093 / 1,093 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,093 / 1,093 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,093 / 1,093 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,093 / 1,093 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,093 / 1,093 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,093 / 1,093 |
| Equipment / loop type | HP - Split System | 1,093 / 1,093 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,093 / 1,093 |
| Compressor staging | Continuously variable | 1,093 / 1,093 |
| Connected capability | No | 1,093 / 1,093 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X36M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217942167 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4553168 → |
EVD5X30M17A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 217940859 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4553197 → |
EVD5X31M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217941070 | 19.00 | 8.50 | 21600 | 1.92 | EPA 4553248 → |
EVD5X31M17A*+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 217941086 | 19.00 | 8.50 | 21800 | 1.92 | EPA 4553265 → |
EVD5X25M17A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 217940101 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4553344 → |
EVD5X36M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 217942437 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4553349 → |
EVD5X36M21A*+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 217942482 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4553356 → |
EVD5X36M21A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217942467 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4553381 → |
EVD5X36M21A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 217942664 | 19.00 | 8.50 | 21200 | 1.90 | EPA 4553395 → |
EVD5X38M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217944300 | 19.00 | 8.50 | 21800 | 1.92 | EPA 4553418 → |
EVD5X38M17A*+ furnace: *97CTN0601716A*Cold climate designationAHRI reference: 217944315 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4553432 → |
EVD5X38M17A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 217944330 | 19.00 | 8.50 | 21800 | 1.92 | EPA 4553448 → |
EVD5X30M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217940388 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4553464 → |
EVD5X30M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 217940403 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4553478 → |
EVD5X30M17A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 217940418 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4553495 → |
EVD5X30M17A*+ furnace: *80MSU0601716A*Cold climate designationAHRI reference: 217940433 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4553509 → |
EVM5X31M17A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 217937314 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4553581 → |
EVD5X36M17A*+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 217941479 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4553610 → |
EVD5X36M17A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217941494 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4553626 → |
EVM5X25M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217936209 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4553667 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →