Q5H9V24*K*AAA*
QuietComfort 19 SEER2 VS HP
1,093 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,093 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,093 / 1,093 |
| EER2 · BTU/Wh | 11.5–14 | 1,093 / 1,093 |
| HSPF2 · BTU/Wh | 8–10 | 1,093 / 1,093 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,093 / 1,093 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,093 / 1,093 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,093 / 1,093 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,093 / 1,093 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,093 / 1,093 |
| Equipment / loop type | HP - Split System | 1,093 / 1,093 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,093 / 1,093 |
| Compressor staging | Continuously variable | 1,093 / 1,093 |
| Connected capability | No | 1,093 / 1,093 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
QFVA5D3617X*Cold climate designationAHRI reference: 218695498 | 19.50 | 8.60 | 21200 | 1.90 | EPA 4683329 → |
EVD5X37M21A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217943070 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4547609 → |
EVD5X37M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 217943085 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4547623 → |
EVM5X32M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 217937874 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4547635 → |
EVD5X30M17A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217940328 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4547641 → |
EVD5X30M17A*+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 217940343 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4547657 → |
EVD5X30M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 217940358 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4547673 → |
EVD5X30M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 217940373 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4547687 → |
EVD5X36M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217941691 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4547732 → |
EVM5X32M17A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 217937889 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4547808 → |
EVM5X32M17A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 217937904 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4547821 → |
EVM5X31M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 217937269 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4547870 → |
EVM5X31M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 217937284 | 19.00 | 8.50 | 21600 | 1.92 | EPA 4547885 → |
EVD5X37M21A*+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 217943176 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4547911 → |
EVD5X37M21A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217943040 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4547918 → |
EVD5X37M21A*+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 217943055 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4547934 → |
EVM5X31M17A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 217937299 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4547979 → |
EVM5X25M17A*+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 217935967 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4548067 → |
EVM5X25M17A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 217935982 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4548082 → |
EVM5X25M17A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217935997 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4548096 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →