Comfortmaker / AIR-SOURCE HEAT PUMP

N5H9V60*K*AAA*

Performance 19 SEER2 VS HP · source records, page 4

212 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.5BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for N5H9V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 212 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.5212 / 212
EER2 · BTU/Wh10–12212 / 212
HSPF2 · BTU/Wh8–9212 / 212
Cooling capacity · BTU/h54,000–57,500212 / 212
Heating capacity at 47°F / 8.3°C · BTU/h56,500–62,000212 / 212
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500212 / 212
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000212 / 212
COP at 5°F / −15°C1.94–2.16212 / 212
Equipment / loop typeHP - Split System212 / 212
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)212 / 212
Compressor stagingContinuously variable212 / 212
Connected capabilityNo212 / 212

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X60M24A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 21793151016.009.00405002.12EPA 4543536
EA*5X60M24A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 21793146516.008.50405002.00EPA 4543558
EA*5X60M24A*+ furnace: *80VSL1352422B*AHRI reference: 21793152516.009.00400002.12EPA 4543565
EA*5X61M24A*+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 21793268216.008.50410002.00EPA 4543717
EA*5X61M24A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 21793271216.009.00410002.14EPA 4543782
EA*5X61M24A*+ furnace: *96VSN1202422B*AHRI reference: 21793272716.009.00405002.14EPA 4543796
EA*5X61M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 21793214116.009.00410002.14EPA 4543826
EA*5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 21793215616.009.00405002.14EPA 4543841
EA*5X61M21A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21793212616.009.00410002.14EPA 4543914
EA*5X61M24A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 21793277216.008.50410002.05EPA 4544232
EA*5X61M24A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21793280216.009.00410002.14EPA 4544429
EA*5X61M24A*+ furnace: *96CTN1202422B*AHRI reference: 21793281716.009.00405002.14EPA 4544444
EA*5X60M24A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 21793149516.009.00405002.12EPA 4544479
EA*5X60M24A*+ furnace: *80MSU0802120A*Cold climate designationAHRI reference: 21793154016.008.50405002.00EPA 4544493
EA*5X60M24A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 21793163016.009.00405002.12EPA 4544508
EA*5X60M24A*+ furnace: *97VTN1002122A*AHRI reference: 21793196116.009.00400002.14EPA 4544603
EA*5X60M24A*+ furnace: OLV154F20ACold climate designationAHRI reference: 21793199116.009.00410002.12EPA 4544619
EA*5X61M24A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21793256116.009.00410002.14EPA 4544771
EA*5X61M24A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21793257616.009.00410002.14EPA 4544786
EA*5X61M24A*+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 21793259116.009.00410002.14EPA 4544835

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →