| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17.5 | 212 / 212 |
| EER2 · BTU/Wh | 10–12 | 212 / 212 |
| HSPF2 · BTU/Wh | 8–9 | 212 / 212 |
| Cooling capacity · BTU/h | 54,000–57,500 | 212 / 212 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,500–62,000 | 212 / 212 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 48,000–50,500 | 212 / 212 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–42,000 | 212 / 212 |
| COP at 5°F / −15°C | 1.94–2.16 | 212 / 212 |
| Equipment / loop type | HP - Split System | 212 / 212 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 212 / 212 |
| Compressor staging | Continuously variable | 212 / 212 |
| Connected capability | No | 212 / 212 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
QFVA5D6021X*Cold climate designationAHRI reference: 218695577 | 17.50 | 8.10 | 40000 | 2.00 | EPA 4683250 → |
FTMA5B60L0D*Cold climate designationAHRI reference: 217918387 | 17.00 | 9.00 | 41000 | 2.12 | EPA 4538453 → |
EA*5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 217932516 | 16.50 | 8.50 | 40500 | 2.05 | EPA 4541976 → |
EA*5X61M24A*+ furnace: *80CSU0802120B*AHRI reference: 217932441 | 16.50 | 8.50 | 40500 | 2.05 | EPA 4547276 → |
EVM5X60M21A*+ furnace: *80VTL1102122B*AHRI reference: 217918627 | 16.00 | 8.00 | 39000 | 1.96 | EPA 4536529 → |
EVM5X60M21A*+ furnace: *95CSU1002122B*AHRI reference: 217918657 | 16.00 | 8.00 | 39000 | 1.96 | EPA 4536542 → |
EVM5X61M24A*+ furnace: *97VTN1002122A*AHRI reference: 217919893 | 16.00 | 8.00 | 40500 | 1.96 | EPA 4536585 → |
EVD5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 217921051 | 16.00 | 8.00 | 40500 | 1.96 | EPA 4536668 → |
EVD5X61M21A*+ furnace: *97CMN1002122B*AHRI reference: 217921126 | 16.00 | 8.00 | 40500 | 1.96 | EPA 4536677 → |
EVM5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 217918898 | 16.00 | 8.00 | 39500 | 1.96 | EPA 4536988 → |
EVM5X60M21A*+ furnace: *97VTN1002120A*AHRI reference: 217918928 | 16.00 | 8.00 | 39500 | 1.94 | EPA 4537015 → |
EVM5X60M21A*+ furnace: *80CTL0902120B*AHRI reference: 217918567 | 16.00 | 8.00 | 39500 | 1.94 | EPA 4537066 → |
EVM5X60M21A*+ furnace: *80CTL1102120B*AHRI reference: 217918582 | 16.00 | 8.00 | 39500 | 1.94 | EPA 4537083 → |
EVM5X60M21A*+ furnace: *97CMN1002122B*AHRI reference: 217918702 | 16.00 | 8.00 | 39500 | 1.94 | EPA 4537220 → |
EVD5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 217921201 | 16.00 | 8.00 | 40500 | 1.96 | EPA 4537350 → |
EVD5X61M21A*+ furnace: *96CTN1002122B*AHRI reference: 217921231 | 16.00 | 8.00 | 40500 | 1.96 | EPA 4537364 → |
EVM5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 217919410 | 16.00 | 8.00 | 41000 | 1.96 | EPA 4537806 → |
EVM5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 217919425 | 16.00 | 8.00 | 41000 | 1.96 | EPA 4537822 → |
EVD5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 217920961 | 16.00 | 8.00 | 40000 | 1.98 | EPA 4537960 → |
EVD5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 217920976 | 16.00 | 8.00 | 40500 | 1.96 | EPA 4537975 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →