Each efficiency range summarizes published EPA records for N5H9V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 450 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 450 / 450 |
| EER2 · BTU/Wh | 10.5–13.5 | 450 / 450 |
| HSPF2 · BTU/Wh | 7.8–9 | 450 / 450 |
| Cooling capacity · BTU/h | 33,400–37,600 | 450 / 450 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,800–37,400 | 450 / 450 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,200–37,600 | 450 / 450 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–26,600 | 450 / 450 |
| COP at 5°F / −15°C | 1.9–2.18 | 450 / 450 |
| Equipment / loop type | HP - Split System | 450 / 450 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 450 / 450 |
| Compressor staging | Continuously variable | 450 / 450 |
| Connected capability | No | 450 / 450 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X36M17A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 217909163 | 15.20 | 8.50 | 26000 | 2.00 | EPA 4533290 → |
EVM5X36M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 217909178 | 15.20 | 8.50 | 26000 | 2.02 | EPA 4533303 → |
EVD5X36M21A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 217911732 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4533337 → |
EVD5X36M21A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217911762 | 15.20 | 8.50 | 26000 | 2.00 | EPA 4533370 → |
EVD5X42M21A*+ furnace: *96VSN1002120B*Cold climate designationAHRI reference: 217913865 | 15.20 | 8.50 | 26200 | 2.00 | EPA 4533387 → |
EVD5X48M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217914561 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4533481 → |
EVD5X37M21A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217912262 | 15.20 | 8.50 | 26600 | 2.02 | EPA 4533616 → |
EVD5X48M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217914577 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4533641 → |
EVM5X43M21A*+ furnace: OMV098J12*Cold climate designationAHRI reference: 217910311 | 15.20 | 8.50 | 25800 | 2.04 | EPA 4533672 → |
EVM5X48M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217910749 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4533688 → |
EVM5X48M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217910765 | 15.20 | 8.50 | 26200 | 2.02 | EPA 4533704 → |
EVD5X37M21A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217912367 | 15.20 | 8.50 | 26600 | 2.02 | EPA 4533804 → |
EVM5X43M21A*+ furnace: OMV112K14ACold climate designationAHRI reference: 217910326 | 15.20 | 8.50 | 25600 | 2.02 | EPA 4533857 → |
EVM5X49M21A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 217910945 | 15.20 | 8.50 | 26600 | 2.00 | EPA 4533911 → |
EVM5X43M21A*+ furnace: *96VSN0401712B*Cold climate designationAHRI reference: 217909843 | 15.20 | 8.50 | 25400 | 2.06 | EPA 4533972 → |
EVM5X48M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 217910825 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4534031 → |
EVD5X38M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 217912716 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4534037 → |
EVD5X38M17A*+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 217912883 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4534153 → |
EVD5X38M17A*+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 217912898 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4534168 → |
EVD5X42M21A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 217913549 | 15.20 | 8.50 | 26400 | 2.02 | EPA 4534193 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.