Comfortmaker / AIR-SOURCE HEAT PUMP

N5H9V36*K*AAA*

Performance 19 SEER2 VS HP · source records, page 15

450 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity33,400–37,600BTU/h

Each efficiency range summarizes published EPA records for N5H9V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 450 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18450 / 450
EER2 · BTU/Wh10.5–13.5450 / 450
HSPF2 · BTU/Wh7.8–9450 / 450
Cooling capacity · BTU/h33,400–37,600450 / 450
Heating capacity at 47°F / 8.3°C · BTU/h31,800–37,400450 / 450
Heating capacity at 17°F / −8.3°C · BTU/h25,200–37,600450 / 450
Heating capacity at 5°F / −15°C · BTU/h24,600–26,600450 / 450
COP at 5°F / −15°C1.9–2.18450 / 450
Equipment / loop typeHP - Split System450 / 450
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)450 / 450
Compressor stagingContinuously variable450 / 450
Connected capabilityNo450 / 450

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X42M21A*+ furnace: *80VSL0902120B*AHRI reference: 21791357915.208.00262002.08EPA 4530890 →
EVM5X36M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 21790895115.208.50256002.02EPA 4530992 →
EVD5X38M17A*+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 21791297315.208.50262002.00EPA 4531175 →
EVD5X38M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 21791300415.208.50264002.02EPA 4531200 →
EVM5X48M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21791053615.208.50262002.02EPA 4531339 →
EVD5X38M17A*+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 21791295815.208.50264002.02EPA 4531379 →
EVM5X36M17A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 21790902615.208.50258002.04EPA 4531398 →
EVD5X48M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 21791419815.208.50262002.02EPA 4531508 →
EVD5X48M21A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 21791434815.208.50266002.00EPA 4531547 →
EVD5X36M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 21791209515.208.50262002.02EPA 4531674 →
EVD5X36M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21791211115.208.50262002.02EPA 4531690 →
EVD5X48M21A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 21791430315.208.50264002.00EPA 4531754 →
EVD5X48M21A*+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21791431815.208.50262002.02EPA 4531772 →
EVD5X37M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 21791264115.208.50264002.02EPA 4531840 →
EVD5X37M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 21791265615.208.50262002.02EPA 4531853 →
EVD5X37M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 21791256515.208.50264002.02EPA 4531861 →
EVD5X37M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 21791258115.208.50262002.02EPA 4531879 →
EVM5X48M21A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 21791055115.208.50266002.00EPA 4532119 →
EVD5X48M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 21791436415.208.50262002.02EPA 4532188 →
EVD5X36M17A*+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 21791123315.208.50258002.04EPA 4532242 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →