N5H9V24*K*AAA*
Performance 19 SEER2 VS HP · source records, page 27
1,093 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H9V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,093 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,093 / 1,093 |
| EER2 · BTU/Wh | 11.5–14 | 1,093 / 1,093 |
| HSPF2 · BTU/Wh | 8–10 | 1,093 / 1,093 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,093 / 1,093 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,093 / 1,093 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,093 / 1,093 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,093 / 1,093 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,093 / 1,093 |
| Equipment / loop type | HP - Split System | 1,093 / 1,093 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,093 / 1,093 |
| Compressor staging | Continuously variable | 1,093 / 1,093 |
| Connected capability | No | 1,093 / 1,093 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X30M17A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 217936717 | 18.00 | 8.50 | 21600 | 1.90 | EPA 4550375 → |
EVD5X38M17A*+ furnace: *96VTN0401712B*Cold climate designationAHRI reference: 217944354 | 18.00 | 8.50 | 22000 | 1.92 | EPA 4550547 → |
EVM5X24M17A*+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 217935477 | 18.00 | 8.50 | 21000 | 1.88 | EPA 4550649 → |
EVM5X24M17A*+ furnace: OMV112K14ACold climate designationAHRI reference: 217935810 | 18.00 | 8.50 | 21200 | 1.90 | EPA 4550746 → |
EVD5X36M17A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 217941760 | 18.00 | 8.50 | 21600 | 1.88 | EPA 4550831 → |
EVD5X36M17A*+ furnace: OLV098A12*Cold climate designationAHRI reference: 217941837 | 18.00 | 8.50 | 21800 | 1.90 | EPA 4550880 → |
EVM5X24M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 217935552 | 18.00 | 8.50 | 21200 | 1.88 | EPA 4550956 → |
EVD5X38M17A*+ furnace: *96VSN0401410B*Cold climate designationAHRI reference: 217944203 | 18.00 | 8.50 | 22200 | 1.92 | EPA 4551004 → |
EVM5X24M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 217935537 | 18.00 | 8.50 | 21000 | 1.88 | EPA 4551105 → |
EVM5X36M17A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 217938608 | 18.00 | 8.50 | 21600 | 1.90 | EPA 4551171 → |
EVD5X36M17A*+ furnace: *96VSN0601412B*Cold climate designationAHRI reference: 217941594 | 18.00 | 8.50 | 21600 | 1.88 | EPA 4551372 → |
EVM5X25M17A*+ furnace: *96VSN0601412B*Cold climate designationAHRI reference: 217936112 | 18.00 | 8.50 | 21600 | 1.90 | EPA 4551418 → |
EVD5X37M21A*+ furnace: *96VSN0401712B*Cold climate designationAHRI reference: 217943274 | 18.00 | 8.50 | 21600 | 1.90 | EPA 4551488 → |
EVM5X36M17A*+ furnace: OMV098J12*Cold climate designationAHRI reference: 217938700 | 18.00 | 8.50 | 21800 | 1.90 | EPA 4551655 → |
EVM5X30M17A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 217936838 | 18.00 | 8.50 | 21600 | 1.88 | EPA 4551920 → |
EVM5X36M17A*+ furnace: OLV098A12*Cold climate designationAHRI reference: 217938685 | 18.00 | 8.50 | 21800 | 1.90 | EPA 4551989 → |
EVM5X24M17A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 217935582 | 18.00 | 8.50 | 21200 | 1.88 | EPA 4552064 → |
EVD5X36M17A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 217941639 | 18.00 | 8.50 | 21600 | 1.90 | EPA 4552212 → |
EVD5X24M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 217939351 | 18.00 | 8.50 | 21000 | 1.88 | EPA 4552427 → |
EVD5X24M17A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 217939367 | 18.00 | 8.50 | 20800 | 1.86 | EPA 4552444 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.