Comfortmaker / AIR-SOURCE HEAT PUMP

N5H8T60*K*AAA*

2-STAGE 18 SEER HP · source records, page 3

122 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 122 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.5122 / 122
EER2 · BTU/Wh11.7–13122 / 122
HSPF2 · BTU/Wh7.8–8.5122 / 122
Cooling capacity · BTU/h54,000–58,000122 / 122
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,500122 / 122
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,500122 / 122
Heating capacity at 5°F / −15°C · BTU/h29,600–31,800122 / 122
COP at 5°F / −15°C2.1–2.34122 / 122
Equipment / loop typeHP - Split System122 / 122
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)122 / 122
Compressor stagingTwo-stage122 / 122
Connected capabilityNo122 / 122

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 21562584916.008.10298002.24EPA 3950215
EVM5X60M21A*+ furnace: *80MSU1002120A*AHRI reference: 21562586816.008.10304002.24EPA 3950233
EVM5X60M21A*+ furnace: *80CTL0902120B*AHRI reference: 21562591216.008.10304002.22EPA 3950250
EVM5X60M21A*+ furnace: *80CTL1102120B*AHRI reference: 21562592616.008.10304002.24EPA 3950262
EVM5X60M21A*+ furnace: *80VTL1102122B*AHRI reference: 21562595916.008.10300002.24EPA 3950280
EVM5X60M21A*+ furnace: *95CSU1002122B*AHRI reference: 21562598816.008.10300002.24EPA 3950298
EVM5X60M21A*+ furnace: *95MSU1002120A*AHRI reference: 21562611116.008.10302002.22EPA 3950312
EVM5X60M21A*+ furnace: *95MSU1002122A*AHRI reference: 21562612716.008.10302002.22EPA 3950328
EVM5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 21562620516.008.10300002.24EPA 3950343
EVM5X61M24A*+ furnace: *80VSL0902120B*AHRI reference: 21562650516.008.50318002.32EPA 3950356
EVM5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 21562654716.008.50316002.32EPA 3950372
EVD5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 21562736316.008.10302002.20EPA 3950525
EVD5X61M21A*+ furnace: *80VSL0902120B*AHRI reference: 21562775116.008.10310002.22EPA 3950539
EVD5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 21562778616.008.10306002.22EPA 3950554
EVD5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 21562780516.008.10310002.20EPA 3950623
EVD5X61M21A*+ furnace: *80VTL0902120B*AHRI reference: 21562786616.008.10310002.22EPA 3950663
EVD5X61M21A*+ furnace: *95CSU1002122B*AHRI reference: 21562791116.008.10308002.20EPA 3950675
EVD5X61M21A*+ furnace: *95MSU1002120A*AHRI reference: 21562801516.008.10314002.18EPA 3950691
EVD5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 21562803116.008.10310002.20EPA 3950709
EVD5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 21562810916.008.10308002.22EPA 3950722

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →