N5H8T60*K*AAA*
2-STAGE 18 SEER HP
122 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 122 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–17.5 | 122 / 122 |
| EER2 · BTU/Wh | 11.7–13 | 122 / 122 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 122 / 122 |
| Cooling capacity · BTU/h | 54,000–58,000 | 122 / 122 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,500–61,500 | 122 / 122 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 36,200–38,500 | 122 / 122 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,600–31,800 | 122 / 122 |
| COP at 5°F / −15°C | 2.1–2.34 | 122 / 122 |
| Equipment / loop type | HP - Split System | 122 / 122 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 122 / 122 |
| Compressor staging | Two-stage | 122 / 122 |
| Connected capability | No | 122 / 122 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FTMA5B60L0D*AHRI reference: 215560748 | 17.50 | 8.10 | 30200 | 2.30 | EPA 3982840 → |
QFVA5D6021X*AHRI reference: 218695466 | 17.50 | 8.10 | 31400 | 2.34 | EPA 4683361 → |
EA*5X60M24A*+ furnace: *80MSU0802120A*AHRI reference: 215629096 | 16.50 | 8.00 | 29600 | 2.30 | EPA 3951008 → |
EA*5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 215629895 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951144 → |
EA*5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 215629973 | 16.50 | 8.10 | 30000 | 2.14 | EPA 3951216 → |
EA*5X61M24A*+ furnace: *80CSU0802120A*AHRI reference: 215629986 | 16.50 | 7.80 | 31400 | 2.22 | EPA 3951247 → |
EA*5X61M24A*+ furnace: *80VSL1102122B*AHRI reference: 215630027 | 16.50 | 8.10 | 29800 | 2.14 | EPA 3951389 → |
EA*5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 215630040 | 16.50 | 8.00 | 30000 | 2.30 | EPA 3951399 → |
EA*5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 215630056 | 16.50 | 8.00 | 29800 | 2.30 | EPA 3951418 → |
EA*5X61M24A*+ furnace: *80MSU1002120A*AHRI reference: 215630075 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951439 → |
EA*5X61M21A*+ furnace: *80VSL1102122B*AHRI reference: 215629582 | 16.50 | 8.10 | 30000 | 2.12 | EPA 3951535 → |
EA*5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 215629617 | 16.50 | 8.00 | 29800 | 2.30 | EPA 3951573 → |
EA*5X61M24A*+ furnace: *80CTL0902120B*AHRI reference: 215630105 | 16.50 | 8.10 | 30200 | 2.26 | EPA 3951611 → |
EA*5X61M24A*+ furnace: *80CTL1102120B*AHRI reference: 215630119 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951625 → |
EA*5X61M24A*+ furnace: *80CTL1352422B*AHRI reference: 215630133 | 16.50 | 8.00 | 30200 | 2.30 | EPA 3951637 → |
EA*5X61M24A*+ furnace: *80VTL1102122B*AHRI reference: 215630166 | 16.50 | 8.10 | 30000 | 2.14 | EPA 3951671 → |
EA*5X61M24A*+ furnace: *95CSU1002122B*AHRI reference: 215630203 | 16.50 | 8.00 | 30000 | 2.30 | EPA 3951707 → |
EA*5X61M21A*+ furnace: *80CTL1102120B*AHRI reference: 215629694 | 16.50 | 8.00 | 30400 | 2.25 | EPA 3951765 → |
EA*5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 215629727 | 16.50 | 8.00 | 30000 | 2.30 | EPA 3951798 → |
EA*5X61M24A*+ furnace: *97CMN1002122B*AHRI reference: 215630245 | 16.50 | 8.10 | 30400 | 2.12 | EPA 3951808 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →