N5H8T48*K*AAA*
2-STAGE 18 SEER HP · source records, page 4
407 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 407 / 407 |
| EER2 · BTU/Wh | 11.7–13.5 | 407 / 407 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 407 / 407 |
| Cooling capacity · BTU/h | 45,500–50,500 | 407 / 407 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,500–52,500 | 407 / 407 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,000–32,600 | 407 / 407 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,800–26,600 | 407 / 407 |
| COP at 5°F / −15°C | 2.06–2.32 | 407 / 407 |
| Equipment / loop type | HP - Split System | 407 / 407 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 407 / 407 |
| Compressor staging | Two-stage | 407 / 407 |
| Connected capability | No | 407 / 407 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X49M24A*+ furnace: *80VSL0902120B*AHRI reference: 215624433 | 17.00 | 8.10 | 25000 | 2.10 | EPA 3948673 → |
EVD5X49M24A*+ furnace: *80VSL1102122B*AHRI reference: 215624446 | 17.00 | 8.10 | 25000 | 2.10 | EPA 3948687 → |
EVD5X49M24A*+ furnace: *80VSL1352422B*AHRI reference: 215624459 | 17.00 | 8.10 | 25000 | 2.10 | EPA 3948698 → |
EVD5X49M24A*+ furnace: *80VTL0902120B*AHRI reference: 215624508 | 17.00 | 8.10 | 25000 | 2.10 | EPA 3948748 → |
EVD5X60M21A*+ furnace: *80CTL1102120B*AHRI reference: 215624817 | 17.00 | 8.10 | 25000 | 2.10 | EPA 3948863 → |
EVD5X60M21A*+ furnace: *80VTL1102122B*AHRI reference: 215624834 | 17.00 | 8.10 | 24400 | 2.14 | EPA 3948882 → |
EVD5X60M21A*+ furnace: *97CMN0802120B*AHRI reference: 215624877 | 17.00 | 8.10 | 25200 | 2.08 | EPA 3948909 → |
EVD5X49M24A*+ furnace: *95MSU1002122A*AHRI reference: 215624633 | 17.00 | 8.10 | 24800 | 2.12 | EPA 3948945 → |
EVD5X49M24A*+ furnace: *96VTN1002122B*AHRI reference: 215624711 | 17.00 | 8.50 | 24800 | 2.12 | EPA 3949046 → |
EVD5X60M21A*+ furnace: *80CSU1002120A*AHRI reference: 215624724 | 17.00 | 8.10 | 25200 | 2.10 | EPA 3949058 → |
EVD5X60M21A*+ furnace: *95MSU1002120A*AHRI reference: 215624939 | 17.00 | 8.10 | 24800 | 2.12 | EPA 3949080 → |
EVD5X60M21A*+ furnace: *96CTN0802120B*AHRI reference: 215624955 | 17.00 | 8.10 | 25200 | 2.10 | EPA 3949096 → |
EVD5X60M21A*+ furnace: *80VSL1102122B*AHRI reference: 215624738 | 17.00 | 8.10 | 24400 | 2.12 | EPA 3949144 → |
EVD5X60M21A*+ furnace: *80MSU0601716A*AHRI reference: 215624754 | 17.00 | 8.10 | 25000 | 2.10 | EPA 3949161 → |
EVD5X60M21A*+ furnace: *80MSU1002120A*AHRI reference: 215624773 | 17.00 | 8.10 | 24800 | 2.12 | EPA 3949182 → |
EVD5X60M21A*+ furnace: *80CTL0902120B*AHRI reference: 215624803 | 17.00 | 8.10 | 24600 | 2.12 | EPA 3949207 → |
EVD5X61M21A*+ furnace: *80VSL0902120B*AHRI reference: 215625018 | 17.00 | 8.50 | 24800 | 2.14 | EPA 3949230 → |
EVD5X61M24A*+ furnace: *80MSU1002120A*AHRI reference: 215625430 | 17.00 | 8.50 | 25000 | 2.26 | EPA 3949376 → |
EVD5X61M24A*+ furnace: *96VSN1002120B*AHRI reference: 215625599 | 17.00 | 8.10 | 25400 | 2.10 | EPA 3949377 → |
EVD5X61M24A*+ furnace: *96VSN1202422B*AHRI reference: 215625612 | 17.00 | 8.50 | 25200 | 2.24 | EPA 3949387 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.