N5H8T48*K*AAA*
2-STAGE 18 SEER HP · source records, page 10
407 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 407 / 407 |
| EER2 · BTU/Wh | 11.7–13.5 | 407 / 407 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 407 / 407 |
| Cooling capacity · BTU/h | 45,500–50,500 | 407 / 407 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,500–52,500 | 407 / 407 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,000–32,600 | 407 / 407 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,800–26,600 | 407 / 407 |
| COP at 5°F / −15°C | 2.06–2.32 | 407 / 407 |
| Equipment / loop type | HP - Split System | 407 / 407 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 407 / 407 |
| Compressor staging | Two-stage | 407 / 407 |
| Connected capability | No | 407 / 407 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X60M21A*+ furnace: *96VTN1002120B*AHRI reference: 215624990 | 16.50 | 8.10 | 24600 | 2.14 | EPA 3949130 → |
EVD5X60M21A*+ furnace: *80CTL0702120B*AHRI reference: 215624789 | 16.50 | 8.10 | 25600 | 2.06 | EPA 3949192 → |
EVD5X61M21A*+ furnace: *80CTL0702120B*AHRI reference: 215625101 | 16.50 | 8.10 | 25600 | 2.08 | EPA 3949315 → |
EVD5X61M24A*+ furnace: *95MSU0802120A*AHRI reference: 215625628 | 16.50 | 8.10 | 25200 | 2.12 | EPA 3949402 → |
EVD5X61M21A*+ furnace: *95MSU0802120A*AHRI reference: 215625262 | 16.50 | 8.10 | 25200 | 2.10 | EPA 3949561 → |
EVD5X61M24A*+ furnace: *95CSU0802120B*AHRI reference: 215625530 | 16.50 | 8.10 | 25600 | 2.08 | EPA 3949647 → |
EVD5X61M24A*+ furnace: *97CMN1202422B*AHRI reference: 215625572 | 16.50 | 8.10 | 25200 | 2.12 | EPA 3949678 → |
EVD5X61M24A*+ furnace: *80CTL0702120B*AHRI reference: 215625446 | 16.50 | 8.10 | 25600 | 2.10 | EPA 3949780 → |
EVD5X61M24A*+ furnace: *96CTN0802120B*AHRI reference: 215625677 | 16.50 | 8.10 | 25600 | 2.10 | EPA 3950007 → |
EVD5X61M24A*+ furnace: *96VTN1202422B*AHRI reference: 215625773 | 16.50 | 8.10 | 25200 | 2.12 | EPA 3950168 → |
EVD5X48M21A*+ furnace: *80VSL1102122B*AHRI reference: 215628846 | 16.50 | 8.10 | 24200 | 2.14 | EPA 3950386 → |
EVD5X61M21A*+TDRAHRI reference: 215628703 | 16.50 | 8.10 | 24200 | 2.16 | EPA 3950479 → |
EVD5X61M24A*+TDRAHRI reference: 215628722 | 16.50 | 8.10 | 24200 | 2.16 | EPA 3950493 → |
EA*5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 215628833 | 16.50 | 8.10 | 25200 | 2.24 | EPA 3950511 → |
EVD5X60M21A*+TDRAHRI reference: 215628665 | 16.50 | 8.00 | 24000 | 2.15 | EPA 3950635 → |
EVM5X49M21A*+TDRAHRI reference: 215628532 | 16.50 | 8.00 | 24000 | 2.15 | EPA 3950774 → |
EVM5X60M21A*+TDRAHRI reference: 215628551 | 16.50 | 8.00 | 24000 | 2.15 | EPA 3950790 → |
EVM5X61M24A*+TDRAHRI reference: 215628589 | 16.50 | 8.10 | 24200 | 2.16 | EPA 3950829 → |
EA*5X60M24A*+ furnace: *80MSU0802120A*AHRI reference: 215631863 | 16.50 | 8.10 | 25600 | 2.20 | EPA 3952580 → |
EA*5X61M21A*+ furnace: *80CTL0902120B*AHRI reference: 215632474 | 16.50 | 8.10 | 25400 | 2.22 | EPA 3952768 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →