D5CUHAH36AAK+KSAIC0701230
Crossover Heat Pump · source records, page 11
316 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH36AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 316 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 316 / 316 |
| EER2 · BTU/Wh | 9.4–10.5 | 316 / 316 |
| HSPF2 · BTU/Wh | 8.1–9 | 316 / 316 |
| Cooling capacity · BTU/h | 34,200–38,000 | 316 / 316 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,400–40,000 | 316 / 316 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–26,200 | 316 / 316 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,800–31,600 | 316 / 316 |
| COP at 5°F / −15°C | 1.75–1.9 | 316 / 316 |
| Equipment / loop type | HP - Split System | 316 / 316 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 316 / 316 |
| Compressor staging | Continuously variable | 316 / 316 |
| Connected capability | No | 316 / 316 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X37M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 218494599 | 15.50 | 8.50 | 30800 | 1.84 | EPA 4636185 → |
EA*5X37M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218494585 | 15.50 | 8.50 | 30800 | 1.84 | EPA 4636192 → |
EA*5X37M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 218494543 | 15.50 | 8.50 | 30600 | 1.82 | EPA 4636199 → |
EA*5X37M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 218494530 | 15.50 | 8.50 | 30600 | 1.82 | EPA 4636206 → |
EA*5X37M17A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 218494489 | 15.50 | 8.50 | 30600 | 1.84 | EPA 4636227 → |
EA*5X37M17A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 218494476 | 15.50 | 8.50 | 30600 | 1.82 | EPA 4636234 → |
EA*5X37M17A*+ furnace: *80VSL0701412B*Cold climate designationAHRI reference: 218494460 | 15.50 | 8.50 | 30600 | 1.82 | EPA 4636241 → |
EA*5X37M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 218494446 | 15.50 | 8.50 | 30600 | 1.82 | EPA 4636248 → |
EA*5X37M21A*+ furnace: OMV098J12*Cold climate designationAHRI reference: 218494420 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4636255 → |
EA*5X37M21A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218494341 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4636290 → |
EA*5X37M21A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218494259 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4636325 → |
EA*5X37M21A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 218494179 | 15.50 | 8.10 | 30400 | 1.75 | EPA 4636360 → |
EA*5X37M21A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218494125 | 15.50 | 8.50 | 30400 | 1.84 | EPA 4636388 → |
EA*5X42M21A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 218493866 | 15.50 | 8.10 | 30800 | 1.75 | EPA 4636505 → |
EA*5X42M21A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218493852 | 15.50 | 8.10 | 31000 | 1.75 | EPA 4636512 → |
EA*5X42M21A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 218493798 | 15.50 | 8.10 | 30800 | 1.75 | EPA 4636541 → |
EA*5X42M21A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218493785 | 15.50 | 8.10 | 31000 | 1.75 | EPA 4636549 → |
EA*5X42M21A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 218493730 | 15.50 | 8.10 | 30800 | 1.75 | EPA 4636570 → |
EA*5X42M21A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 218493717 | 15.50 | 8.10 | 30800 | 1.75 | EPA 4636577 → |
EA*5X42M21A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 218493703 | 15.50 | 8.10 | 31000 | 1.75 | EPA 4636588 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.