D5CUHAH24AAK+KSAIC0701230
Crossover Heat Pump · source records, page 2
499 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH24AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 499 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 499 / 499 |
| EER2 · BTU/Wh | 10–11 | 499 / 499 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 499 / 499 |
| Cooling capacity · BTU/h | 22,600–25,000 | 499 / 499 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,200–25,800 | 499 / 499 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,800–18,700 | 499 / 499 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,700–20,600 | 499 / 499 |
| COP at 5°F / −15°C | 1.85–2.06 | 499 / 499 |
| Equipment / loop type | HP - Split System | 499 / 499 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 499 / 499 |
| Compressor staging | Continuously variable | 499 / 499 |
| Connected capability | No | 499 / 499 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FMA5X24**AL*Cold climate designationAHRI reference: 218486259 | 17.50 | 9.00 | 19000 | 2.02 | EPA 4631936 → |
FM(C,U)5Z36**AL*Cold climate designationAHRI reference: 218486238 | 17.50 | 9.00 | 19000 | 2.04 | EPA 4631943 → |
FM(C,U)5Z30**AL*Cold climate designationAHRI reference: 218486231 | 17.50 | 9.00 | 19000 | 2.04 | EPA 4631950 → |
EA*5X25M17A*+ furnace: *80MS(N,L)0701412A*Cold climate designationAHRI reference: 218484814 | 17.00 | 8.50 | 18900 | 1.94 | EPA 4629414 → |
EA*5X36M17A*+ furnace: *80MS(N,L)0701712A*Cold climate designationAHRI reference: 218485112 | 17.00 | 8.50 | 19300 | 1.92 | EPA 4629637 → |
EA*5X25M17A*+ furnace: *92MSN0801716A*Cold climate designationAHRI reference: 218484870 | 17.00 | 8.50 | 18900 | 1.94 | EPA 4629856 → |
EA*5X37M21A*+ furnace: *92MSN1002120A*Cold climate designationAHRI reference: 218485417 | 17.00 | 8.50 | 18800 | 1.92 | EPA 4630228 → |
EA*5X37M21A*+ furnace: *92MSN0801716A*Cold climate designationAHRI reference: 218485403 | 17.00 | 8.50 | 18700 | 1.94 | EPA 4630242 → |
EA*5X37M21A*+ furnace: *80MS(N,L)0701712A*Cold climate designationAHRI reference: 218485340 | 17.00 | 8.50 | 18800 | 1.94 | EPA 4630305 → |
EA*5X37M21A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 218487456 | 17.00 | 9.00 | 18900 | 2.02 | EPA 4630739 → |
EA*5X37M21A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 218487449 | 17.00 | 8.50 | 18700 | 1.92 | EPA 4630746 → |
EA*5X37M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 218487442 | 17.00 | 8.50 | 18900 | 1.92 | EPA 4630753 → |
EA*5X37M21A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 218487435 | 17.00 | 9.00 | 18900 | 2.02 | EPA 4630760 → |
EA*5X37M21A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218487428 | 17.00 | 8.50 | 18800 | 1.92 | EPA 4630767 → |
EA*5X37M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 218487421 | 17.00 | 9.00 | 18900 | 2.02 | EPA 4630774 → |
EA*5X37M21A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 218487414 | 17.00 | 8.50 | 18700 | 1.92 | EPA 4630781 → |
EA*5X37M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 218487407 | 17.00 | 8.50 | 18900 | 1.92 | EPA 4630788 → |
EA*5X37M21A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 218487400 | 17.00 | 9.00 | 18900 | 2.02 | EPA 4630795 → |
EA*5X37M21A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218487393 | 17.00 | 8.50 | 18800 | 1.92 | EPA 4630802 → |
EA*5X37M21A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 218487365 | 17.00 | 8.50 | 18700 | 1.92 | EPA 4630830 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.