D5CUHAH24AAK+KSAIC0701230
Crossover Heat Pump · source records, page 10
499 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH24AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 499 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 499 / 499 |
| EER2 · BTU/Wh | 10–11 | 499 / 499 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 499 / 499 |
| Cooling capacity · BTU/h | 22,600–25,000 | 499 / 499 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,200–25,800 | 499 / 499 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,800–18,700 | 499 / 499 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,700–20,600 | 499 / 499 |
| COP at 5°F / −15°C | 1.85–2.06 | 499 / 499 |
| Equipment / loop type | HP - Split System | 499 / 499 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 499 / 499 |
| Compressor staging | Continuously variable | 499 / 499 |
| Connected capability | No | 499 / 499 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X30M14A*+ furnace: *96VSN0601412B*Cold climate designationAHRI reference: 218486693 | 16.50 | 8.50 | 19500 | 1.90 | EPA 4631502 → |
EA*5X30M14A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 218486679 | 16.50 | 8.50 | 19400 | 1.88 | EPA 4631516 → |
EA*5X30M14A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 218486665 | 16.50 | 8.50 | 19400 | 1.88 | EPA 4631530 → |
EA*5X25M17A*+ furnace: OMV112K14ACold climate designationAHRI reference: 218486658 | 16.50 | 9.00 | 19300 | 2.02 | EPA 4631537 → |
EA*5X25M17A*+ furnace: *96VTN0401712B*Cold climate designationAHRI reference: 218486602 | 16.50 | 8.50 | 19100 | 1.92 | EPA 4631593 → |
EA*5X25M17A*+ furnace: *96VTN0401410B*Cold climate designationAHRI reference: 218486595 | 16.50 | 8.50 | 19000 | 1.92 | EPA 4631600 → |
EA*5X25M17A*+ furnace: *96VSN0401712B*Cold climate designationAHRI reference: 218486553 | 16.50 | 8.50 | 19100 | 1.92 | EPA 4631642 → |
EA*5X25M17A*+ furnace: *96VSN0401410B*Cold climate designationAHRI reference: 218486546 | 16.50 | 8.50 | 19000 | 1.92 | EPA 4631649 → |
EA*5X24M17A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 218486462 | 16.50 | 9.00 | 19800 | 2.00 | EPA 4631733 → |
EA*5X24M17A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218486455 | 16.50 | 9.00 | 19800 | 1.98 | EPA 4631740 → |
EA*5X24M17A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 218486448 | 16.50 | 9.00 | 19800 | 2.00 | EPA 4631747 → |
EA*5X24M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218486441 | 16.50 | 9.00 | 19800 | 1.98 | EPA 4631754 → |
EA*5X24M17A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 218486434 | 16.50 | 9.00 | 19800 | 2.00 | EPA 4631761 → |
EA*5X24M17A*+ furnace: *96VTN0401712B*Cold climate designationAHRI reference: 218486427 | 16.50 | 9.00 | 20000 | 2.00 | EPA 4631768 → |
EA*5X24M17A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 218486413 | 16.50 | 9.00 | 19800 | 1.98 | EPA 4631782 → |
EA*5X24M17A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 218486406 | 16.50 | 9.00 | 19800 | 1.98 | EPA 4631789 → |
EA*5X24M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 218486399 | 16.50 | 9.00 | 19800 | 2.00 | EPA 4631796 → |
EA*5X24M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218486392 | 16.50 | 9.00 | 19800 | 1.98 | EPA 4631803 → |
EA*5X24M17A*+ furnace: *96VSN0601412B*Cold climate designationAHRI reference: 218486385 | 16.50 | 9.00 | 19800 | 2.00 | EPA 4631810 → |
EA*5X24M17A*+ furnace: *96VSN0401712B*Cold climate designationAHRI reference: 218486378 | 16.50 | 9.00 | 20000 | 2.00 | EPA 4631817 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →