Comfortmaker / AIR-SOURCE HEAT PUMP

C5H8T60*K*AAA*

Mainline 18 SEER2 HP · source records, page 3

85 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for C5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 85 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.585 / 85
EER2 · BTU/Wh11.7–1385 / 85
HSPF2 · BTU/Wh7.8–8.585 / 85
Cooling capacity · BTU/h54,000–58,00085 / 85
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,50085 / 85
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,50085 / 85
Heating capacity at 5°F / −15°C · BTU/h29,600–31,80085 / 85
COP at 5°F / −15°C2.18–2.3685 / 85
Equipment / loop typeHP - Split System85 / 85
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)85 / 85
Compressor stagingTwo-stage85 / 85
Connected capabilityNo85 / 85

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X60M21A*+ furnace: *80VSL1102122B*AHRI reference: 21634694516.008.10304002.24EPA 3805335
EVD5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 21634696116.008.10304002.26EPA 3805351
EVM5X60M21A*+ furnace: *95MSU1002122A*AHRI reference: 21634623316.008.10302002.24EPA 3805523
EVM5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 21634627316.008.10300002.26EPA 3805532
EVD5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 21634775316.008.50316002.34EPA 3805651
EA*5X61M21A*+ furnace: *96VSN0802120B*AHRI reference: 21634849716.007.80304002.20EPA 3805723
EA*5X61M21A*+ furnace: *96VSN1002120B*AHRI reference: 21634850516.007.80302002.20EPA 3805731
EA*5X61M21A*+ furnace: *95MSU0802120A*AHRI reference: 21634852116.007.80302002.20EPA 3805739
EA*5X61M21A*+ furnace: *95MSU1002120A*AHRI reference: 21634852916.007.80302002.22EPA 3805747
EVD5X60M21A*+ furnace: *80VTL1102122B*AHRI reference: 21634700916.008.10304002.24EPA 3805854
EA*5X61M24A*+ furnace: *80VSL0902120B*AHRI reference: 21634867316.007.80300002.20EPA 3806013
EVD5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 21634712916.008.10302002.24EPA 3806076
EA*5X60M24A*+ furnace: *80VTL0902120B*AHRI reference: 21634810516.007.80298002.22EPA 3806747
EA*5X60M24A*+ furnace: *80VTL1102122B*AHRI reference: 21634811316.007.80298002.22EPA 3806755
EA*5X61M24A*+ furnace: *96VSN0802120B*AHRI reference: 21634880916.007.80302002.22EPA 3806766
EA*5X61M24A*+ furnace: *96VSN1002120B*AHRI reference: 21634881716.007.80302002.22EPA 3806774
EA*5X61M24A*+ furnace: *96VSN1202422B*AHRI reference: 21634882516.007.80300002.20EPA 3806782
EA*5X61M24A*+ furnace: *95MSU0802120A*AHRI reference: 21634883316.007.80302002.22EPA 3806790
EA*5X61M24A*+ furnace: *95MSU1002120A*AHRI reference: 21634884116.007.80302002.20EPA 3806798
EA*5X60M24A*+ furnace: *80VSL0902120B*AHRI reference: 21634803316.007.80298002.22EPA 3806821