C5H8T60*K*AAA*
Mainline 18 SEER2 HP
85 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for C5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 85 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–17.5 | 85 / 85 |
| EER2 · BTU/Wh | 11.7–13 | 85 / 85 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 85 / 85 |
| Cooling capacity · BTU/h | 54,000–58,000 | 85 / 85 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,500–61,500 | 85 / 85 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 36,200–38,500 | 85 / 85 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,600–31,800 | 85 / 85 |
| COP at 5°F / −15°C | 2.18–2.36 | 85 / 85 |
| Equipment / loop type | HP - Split System | 85 / 85 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 85 / 85 |
| Compressor staging | Two-stage | 85 / 85 |
| Connected capability | No | 85 / 85 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FTMA5B60L0D*AHRI reference: 216152724 | 17.50 | 8.10 | 30200 | 2.34 | EPA 3802010 → |
FCMA5B60L0D*+WALLCONAHRI reference: 216349385 | 17.50 | 8.00 | 30200 | 2.30 | EPA 3806248 → |
QFVA5D6021X*AHRI reference: 218695630 | 17.50 | 8.10 | 31400 | 2.34 | EPA 4683197 → |
EA*5X61M24A*+ furnace: *96VTN1002122B*AHRI reference: 216348897 | 16.50 | 8.10 | 29800 | 2.34 | EPA 3802193 → |
EA*5X61M24A*+ furnace: OLV154F20AAHRI reference: 216348913 | 16.50 | 7.80 | 30400 | 2.22 | EPA 3803210 → |
EA*5X61M21A*+ furnace: *80VSL1102122B*AHRI reference: 216348385 | 16.50 | 8.10 | 30000 | 2.30 | EPA 3803642 → |
EA*5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 216348401 | 16.50 | 7.80 | 29800 | 2.24 | EPA 3803658 → |
EA*5X61M21A*+ furnace: *80VTL1102122B*AHRI reference: 216348457 | 16.50 | 7.80 | 30000 | 2.22 | EPA 3804025 → |
EA*5X61M24A*+ furnace: *80VSL1102122B*AHRI reference: 216348681 | 16.50 | 8.10 | 29800 | 2.32 | EPA 3806098 → |
EA*5X61M24A*+ furnace: *80VSL1352422B*AHRI reference: 216348689 | 16.50 | 7.80 | 30000 | 2.22 | EPA 3806107 → |
EA*5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 216348697 | 16.50 | 7.80 | 29800 | 2.24 | EPA 3806114 → |
EA*5X61M24A*+ furnace: *80MSU1002120A*AHRI reference: 216348705 | 16.50 | 7.80 | 30200 | 2.22 | EPA 3806122 → |
EA*5X61M24A*+ furnace: *95MSU1002122A*AHRI reference: 216348849 | 16.50 | 7.80 | 30200 | 2.22 | EPA 3806806 → |
EA*5X60M24A*+ furnace: *80MSU0802120A*AHRI reference: 216348057 | 16.50 | 7.80 | 29600 | 2.22 | EPA 3806845 → |
EA*5X61M24A*+ furnace: *80VTL1102122B*AHRI reference: 216348753 | 16.50 | 8.10 | 30000 | 2.32 | EPA 3806917 → |
EA*5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 216348537 | 16.50 | 7.80 | 30200 | 2.22 | EPA 3807277 → |
EA*5X61M21A*+ furnace: *96VTN1002122B*AHRI reference: 216348577 | 16.50 | 8.10 | 30000 | 2.32 | EPA 3807319 → |
EA*5X60M24A*+ furnace: *96VSN0802120B*AHRI reference: 216348169 | 16.00 | 7.80 | 30000 | 2.20 | EPA 3802062 → |
EA*5X60M24A*+ furnace: *96VSN1202422B*AHRI reference: 216348185 | 16.00 | 7.80 | 29800 | 2.20 | EPA 3802078 → |
EA*5X60M24A*+ furnace: *95MSU0802120A*AHRI reference: 216348193 | 16.00 | 7.80 | 30000 | 2.22 | EPA 3802086 → |