C5H8T48*K*AAA*
Mainline 18 SEER2 HP · source records, page 17
415 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for C5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 415 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 415 / 415 |
| EER2 · BTU/Wh | 11.7–13.5 | 415 / 415 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 415 / 415 |
| Cooling capacity · BTU/h | 45,500–50,500 | 415 / 415 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,500–52,500 | 415 / 415 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,400–32,400 | 415 / 415 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,200–26,600 | 415 / 415 |
| COP at 5°F / −15°C | 2.1–2.34 | 415 / 415 |
| Equipment / loop type | HP - Split System | 415 / 415 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 415 / 415 |
| Compressor staging | Two-stage | 415 / 415 |
| Connected capability | No | 415 / 415 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X48M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 216351658 | 16.00 | 8.00 | 24800 | 2.22 | EPA 3806189 → |
EA*5X48M21A*+ furnace: *80VTL1102122B*AHRI reference: 216351690 | 16.00 | 8.10 | 25000 | 2.26 | EPA 3806205 → |
EVM5X60M24A*+TDRAHRI reference: 216349409 | 16.00 | 7.80 | 24000 | 2.10 | EPA 3806272 → |
EVD5X48M21A*+TDRAHRI reference: 216349425 | 16.00 | 7.80 | 23800 | 2.10 | EPA 3806288 → |
EVD5X48M24A*+TDRAHRI reference: 216349433 | 16.00 | 7.80 | 23800 | 2.12 | EPA 3806296 → |
EA*5X48M21A*+WALLCON+ furnace: *95CSU1002122B*AHRI reference: 216351714 | 16.00 | 8.00 | 24800 | 2.22 | EPA 3806538 → |
EA*5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 216351866 | 16.00 | 8.10 | 24800 | 2.28 | EPA 3806660 → |
EA*5X61M24A*+ furnace: *80MSU1002120A*AHRI reference: 216352690 | 16.00 | 8.10 | 26200 | 2.22 | EPA 3806673 → |
EA*5X61M24A*+ furnace: *80VSL1102122B*AHRI reference: 216352666 | 16.00 | 8.10 | 26000 | 2.22 | EPA 3806693 → |
EA*5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 216351810 | 16.00 | 8.10 | 24800 | 2.26 | EPA 3806726 → |
EA*5X61M21A*+ furnace: *96VTN0802120B*AHRI reference: 216352546 | 16.00 | 8.10 | 25600 | 2.24 | EPA 3806862 → |
EA*5X61M21A*+ furnace: *96VTN1002120B*AHRI reference: 216352554 | 16.00 | 8.10 | 25600 | 2.24 | EPA 3806870 → |
EVM5X48M21A*+WALLCON+ furnace: *95CSU1002122B*AHRI reference: 216349577 | 16.00 | 8.00 | 23400 | 2.18 | EPA 3806925 → |
EVM5X48M21A*+ furnace: *96VSN0802120B*AHRI reference: 216349601 | 16.00 | 8.10 | 24800 | 2.14 | EPA 3806933 → |
EA*5X61M24A*+ furnace: *80VSL0902120B*AHRI reference: 216352658 | 16.00 | 8.10 | 26000 | 2.22 | EPA 3807079 → |
EA*5X61M24A*+ furnace: *80VTL0902120B*AHRI reference: 216352730 | 16.00 | 8.10 | 26000 | 2.22 | EPA 3807080 → |
EA*5X61M24A*+ furnace: *80VTL1102122B*AHRI reference: 216352738 | 16.00 | 8.10 | 25800 | 2.22 | EPA 3807088 → |
EA*5X61M24A*+WALLCON+ furnace: *95CSU1002122B*AHRI reference: 216352754 | 16.00 | 8.00 | 25000 | 2.24 | EPA 3807097 → |
EA*5X48M21A*+ furnace: *80VSL1102122B*AHRI reference: 216351602 | 16.00 | 8.10 | 24800 | 2.26 | EPA 3807243 → |
EA*5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 216351610 | 16.00 | 8.10 | 25000 | 2.26 | EPA 3807251 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →