SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for C5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 188 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5188 / 188
EER2 · BTU/Wh11.7–13188 / 188
HSPF2 · BTU/Wh7.8–8.5188 / 188
Cooling capacity · BTU/h33,800–38,000188 / 188
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000188 / 188
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200188 / 188
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600188 / 188
COP at 5°F / −15°C1.84–2.4188 / 188
Equipment / loop typeHP - Split System188 / 188
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)188 / 188
Compressor stagingTwo-stage188 / 188
Connected capabilityNo188 / 188

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21635731415.508.00193002.24EPA 3807884 →
EA*5X37M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21635732215.508.00193002.24EPA 3807892 →
EA*5X37M21A*+ furnace: *80VTL0902120B*AHRI reference: 21635733815.508.10193002.28EPA 3807908 →
EA*5X37M21A*+ furnace: *80VTL1102122B*AHRI reference: 21635734615.508.10195002.28EPA 3807916 →
EA*5X37M21A*+WALLCON+ furnace: *95CSU1002122B*AHRI reference: 21635737015.508.00193002.24EPA 3807924 →
EA*5X48M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21635875415.508.00191002.26EPA 3807936 →
EA*5X42M21A*+ furnace: *96VTN1002122B*AHRI reference: 21635802615.508.10188002.28EPA 3807940 →
EA*5X48M21A*+ furnace: *96VSN1002120B*AHRI reference: 21635888215.508.10193002.26EPA 3807979 →
EA*5X48M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21635876215.508.00191002.26EPA 3807994 →
EA*5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 21635877815.508.10192002.28EPA 3808010 →
EA*5X48M21A*+ furnace: *80VTL1102122B*AHRI reference: 21635878615.508.10191002.28EPA 3808018 →
ESH5X42M12A*+ furnace: *80MSU0802120A*AHRI reference: 21635965815.508.10190002.28EPA 3808032 →
EA*5X37M21A*+WALLCON+ furnace: *97CMN1002122B*AHRI reference: 21635741015.508.00194002.24EPA 3808066 →
EA*5X37M21A*+ furnace: *96VSN0802120B*AHRI reference: 21635743415.508.10193002.28EPA 3808074 →
EA*5X37M21A*+ furnace: *96VSN1002120B*AHRI reference: 21635744215.508.10194002.28EPA 3808082 →
EA*5X37M21A*+ furnace: *95MSU0802120A*AHRI reference: 21635745815.508.10193002.28EPA 3808098 →
EA*5X37M21A*+ furnace: *95MSU1002120A*AHRI reference: 21635746615.508.10194002.28EPA 3808106 →
EA*5X37M21A*+ furnace: *95MSU1002122A*AHRI reference: 21635747415.508.10194002.30EPA 3808114 →
EA*5X37M21A*+WALLCON+ furnace: *96CTN1002122B*AHRI reference: 21635750615.508.00194002.24EPA 3808122 →
EA*5X43M21A*+ furnace: *80VSL0701716B*AHRI reference: 21635817015.508.10194002.26EPA 3808130 →