Comfortmaker / AIR-SOURCE HEAT PUMP

C5H8T24*K*AAA*

Mainline 18 SEER2 HP

498 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for C5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 498 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5498 / 498
EER2 · BTU/Wh11.7–14498 / 498
HSPF2 · BTU/Wh7.8–8.5498 / 498
Cooling capacity · BTU/h22,200–25,000498 / 498
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400498 / 498
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000498 / 498
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500498 / 498
COP at 5°F / −15°C1.94–2.24498 / 498
Equipment / loop typeHP - Split System498 / 498
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)498 / 498
Compressor stagingTwo-stage498 / 498
Connected capabilityNo498 / 498

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X32M17A*+ furnace: *80MSU0401712A*AHRI reference: 21636152218.507.80108002.08EPA 3808737 →
EVM5X32M17A*+ furnace: *80VSL0701412B*AHRI reference: 21636149818.507.80109002.08EPA 3808741 →
EVD5X37M21A*+ furnace: *96VTN0802120B*AHRI reference: 21636401018.007.80109002.08EPA 3807856 →
EVD5X36M21A*+ furnace: *80VTL1102122B*AHRI reference: 21636329018.007.80108002.08EPA 3807876 →
EVD5X31M17A*+ furnace: *80VSL0451412B*AHRI reference: 21636265018.007.80110002.06EPA 3808263 →
EVD5X31M17A*+ furnace: *80VSL0701716B*AHRI reference: 21636266618.007.80111002.04EPA 3808272 →
EVD5X31M17A*+ furnace: *80VTL0451412B*AHRI reference: 21636271418.007.80110002.06EPA 3808368 →
EVD5X36M21A*+ furnace: *96VTN0802120B*AHRI reference: 21636348218.007.80108002.08EPA 3808392 →
EVM5X31M17A*+ furnace: *96VTN0601716B*AHRI reference: 21636138618.007.80111002.04EPA 3808481 →
EVD5X37M21A*+ furnace: *80VSL0701716B*AHRI reference: 21636367418.007.80109002.06EPA 3808542 →
EVD5X37M21A*+ furnace: *80MSU1002120A*AHRI reference: 21636373018.007.80109002.06EPA 3808649 →
EVM5X31M17A*+ furnace: *96VSN0601716B*AHRI reference: 21636130618.007.80111002.04EPA 3809102 →
FTMA5B36L0C*AHRI reference: 21636890118.008.10107002.14EPA 3809319 →
FCMA5B36L0C*+WALLCONAHRI reference: 21636891718.008.00109002.08EPA 3809335 →
EA*5X37M21A*+WALLCON+ furnace: *97CMN0802120B*AHRI reference: 21636659518.008.10112002.12EPA 3809507 →
EA*5X37M21A*+WALLCON+ furnace: *97CMN1002122B*AHRI reference: 21636660318.008.10112002.12EPA 3809515 →
EA*5X37M21A*+ furnace: *96VSN0601716B*AHRI reference: 21636661918.008.10112002.10EPA 3809532 →
EA*5X37M21A*+ furnace: *96VSN0802120B*AHRI reference: 21636663518.008.50112002.22EPA 3809552 →
EA*5X37M21A*+ furnace: *96VSN1002120B*AHRI reference: 21636664318.008.10111002.12EPA 3809562 →
EA*5X37M21A*+WALLCON+ furnace: *80CSU0401712B*AHRI reference: 21636679518.008.50112002.24EPA 3809676 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →