C5H0V60*K*AAA*
SoftSound 20 VS Heat Pump · source records, page 4
158 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for C5H0V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 158 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.5–19 | 158 / 158 |
| EER2 · BTU/Wh | 8–9.8 | 158 / 158 |
| HSPF2 · BTU/Wh | 8.1–9 | 158 / 158 |
| Cooling capacity · BTU/h | 54,000–58,000 | 158 / 158 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 59,000–63,500 | 54 / 158 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 50,500–57,500 | 158 / 158 |
| Heating capacity at 5°F / −15°C · BTU/h | 41,000–46,000 | 158 / 158 |
| COP at 5°F / −15°C | 1.86–2.1 | 158 / 158 |
| Equipment / loop type | HP - Split System | 158 / 158 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 158 / 158 |
| Compressor staging | Continuously variable | 158 / 158 |
| Connected capability | No | 158 / 158 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X61M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 215677988 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3973319 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215677998 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3973341 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 215678008 | 18.50 | 9.00 | 42000 | 2.00 | EPA 3973349 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215678018 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3973355 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 215678028 | 18.50 | 9.00 | 41500 | 2.02 | EPA 3973362 → |
EA*5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215682578 | 18.50 | 9.00 | 42000 | 1.90 | EPA 3977530 → |
EA*5X60M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 215682588 | 18.50 | 8.50 | 41000 | 2.04 | EPA 3977535 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215682608 | 18.50 | 9.00 | 42000 | 1.90 | EPA 3977557 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215682618 | 18.50 | 9.00 | 41500 | 1.90 | EPA 3977564 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 215682628 | 18.50 | 9.00 | 41500 | 2.02 | EPA 3977581 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215682658 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3977929 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215682688 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3978026 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215682698 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3978033 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 215682708 | 18.50 | 9.00 | 41500 | 2.02 | EPA 3978045 → |
EVM5X60M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215682858 | 18.50 | 9.00 | 45000 | 2.08 | EPA 3978209 → |
EVD5X60M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215683048 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3978232 → |
EVD5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215683098 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3978280 → |
EVD5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 215683108 | 18.50 | 9.00 | 44500 | 2.10 | EPA 3978287 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215682908 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3978343 → |
EVD5X61M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215683228 | 18.50 | 9.00 | 44500 | 2.08 | EPA 3978349 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →