Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X49M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215675578 | 19.00 | 9.00 | 36600 | 2.00 | EPA 3969111 → |
EVM5X49M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 215675598 | 19.00 | 9.00 | 36600 | 2.02 | EPA 3969134 → |
EVM5X49M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 215675628 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3969230 → |
EVM5X49M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215675638 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3969242 → |
EVM5X49M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215675658 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3969261 → |
EVM5X60M21A*+WALLCON+ furnace: *80CSU0601716A*Cold climate designationAHRI reference: 215675668 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3969273 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU0601716A*Cold climate designationAHRI reference: 215675498 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3969306 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 215675508 | 19.00 | 9.00 | 36600 | 2.12 | EPA 3969314 → |
EVM5X60M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215675748 | 19.00 | 9.00 | 36600 | 2.00 | EPA 3969350 → |
EVM5X60M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 215675778 | 19.00 | 9.00 | 36600 | 2.12 | EPA 3969380 → |
EVM5X60M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 215675808 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3969406 → |
EVM5X60M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 215675918 | 19.00 | 9.00 | 36400 | 2.02 | EPA 3969428 → |
EVM5X60M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215675928 | 19.00 | 9.00 | 36600 | 2.00 | EPA 3969440 → |
EVM5X60M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 215675938 | 19.00 | 9.00 | 36600 | 2.00 | EPA 3969447 → |
EVM5X60M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215675948 | 19.00 | 9.00 | 36600 | 2.00 | EPA 3969457 → |
EVM5X61M24A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 215675968 | 19.00 | 9.00 | 36800 | 2.10 | EPA 3969474 → |
EVM5X61M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 215675978 | 19.00 | 9.50 | 36800 | 2.10 | EPA 3969486 → |
EVM5X61M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215676018 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3969531 → |
EVM5X61M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 215676028 | 19.00 | 9.00 | 36600 | 2.10 | EPA 3969541 → |
EVM5X61M24A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 215676038 | 19.00 | 9.00 | 37200 | 1.98 | EPA 3969545 → |