B5H3V60*K*AAA*
SoftSound 23 VS Heat Pump
34 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H3V60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 34 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17.5–20 | 34 / 34 |
| EER2 · BTU/Wh | 10.5–12.5 | 34 / 34 |
| HSPF2 · BTU/Wh | 8–9 | 34 / 34 |
| Cooling capacity · BTU/h | 55,000–58,000 | 34 / 34 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 60,000–61,000 | 34 / 34 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 46,000–49,000 | 34 / 34 |
| Heating capacity at 5°F / −15°C · BTU/h | 44,500–47,500 | 34 / 34 |
| COP at 5°F / −15°C | 1.96–2.18 | 34 / 34 |
| Equipment / loop type | HP - Split System | 34 / 34 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 34 / 34 |
| Compressor staging | Continuously variable | 34 / 34 |
| Connected capability | No | 34 / 34 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FCMA5B60L0D*+WALLCONCold climate designationAHRI reference: 218405899 | 20.00 | 9.00 | 44500 | 2.18 | EPA 4601631 → |
EA*5X61M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 218415019 | 19.00 | 8.50 | 46000 | 2.04 | EPA 4607783 → |
EA*5X61M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218415011 | 19.00 | 8.50 | 46500 | 2.04 | EPA 4607791 → |
EA*5X61M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218415003 | 19.00 | 8.50 | 46500 | 2.06 | EPA 4607799 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 218415075 | 18.50 | 8.50 | 46500 | 2.04 | EPA 4607735 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218415067 | 18.50 | 8.50 | 46500 | 2.04 | EPA 4607743 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 218415059 | 18.50 | 8.50 | 46500 | 2.04 | EPA 4607751 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218415051 | 18.50 | 8.50 | 46500 | 2.04 | EPA 4607759 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218415043 | 18.50 | 8.50 | 46500 | 2.02 | EPA 4607767 → |
EA*5X61M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218415027 | 18.50 | 8.50 | 46500 | 2.02 | EPA 4607775 → |
EA*5X61M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218414995 | 18.50 | 8.50 | 47000 | 2.04 | EPA 4607807 → |
EA*5X60M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 218414979 | 18.50 | 8.50 | 46000 | 2.08 | EPA 4607823 → |
EA*5X60M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218414971 | 18.50 | 8.50 | 46000 | 2.08 | EPA 4607831 → |
EA*5X60M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 218414963 | 18.50 | 8.10 | 46000 | 2.00 | EPA 4607839 → |
EA*5X60M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218414955 | 18.50 | 8.50 | 46000 | 2.08 | EPA 4607847 → |
EA*5X60M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218414931 | 18.50 | 8.10 | 45500 | 2.00 | EPA 4607863 → |
EA*5X60M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 218414915 | 18.50 | 8.10 | 45500 | 2.00 | EPA 4607879 → |
EA*5X60M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218414907 | 18.50 | 8.10 | 45500 | 2.00 | EPA 4607887 → |
EA*5X60M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218414899 | 18.50 | 8.10 | 45500 | 2.00 | EPA 4607895 → |
ESH5X60M12A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 218415163 | 18.00 | 8.10 | 46000 | 2.00 | EPA 4607655 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →