B5H3V36*K*AAA*
SoftSound 23 VS Heat Pump
514 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 514 / 514 |
| EER2 · BTU/Wh | 10–12.5 | 514 / 514 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 514 / 514 |
| Cooling capacity · BTU/h | 32,000–36,000 | 514 / 514 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,400–39,500 | 514 / 514 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 514 / 514 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 514 / 514 |
| COP at 5°F / −15°C | 1.92–2.1 | 514 / 514 |
| Equipment / loop type | HP - Split System | 514 / 514 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 514 / 514 |
| Compressor staging | Continuously variable | 514 / 514 |
| Connected capability | No | 514 / 514 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X61M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 218411803 | 22.50 | 8.50 | 28200 | 2.04 | EPA 4603691 → |
EVM5X61M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218411795 | 22.50 | 8.50 | 28200 | 2.06 | EPA 4603699 → |
EVM5X61M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218411787 | 22.50 | 8.50 | 28200 | 2.06 | EPA 4603707 → |
EVD5X61M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218413147 | 22.50 | 8.50 | 28200 | 2.06 | EPA 4606347 → |
EVD5X61M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218413139 | 22.50 | 8.50 | 28200 | 2.06 | EPA 4606355 → |
EVD5X61M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218413131 | 22.50 | 8.50 | 28200 | 2.06 | EPA 4606363 → |
FCMA5B60L0D*+WALLCONCold climate designationAHRI reference: 218405883 | 22.00 | 9.50 | 25200 | 2.10 | EPA 4601647 → |
EVM5X61M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218411811 | 22.00 | 8.50 | 28200 | 2.06 | EPA 4603683 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 218411779 | 22.00 | 8.50 | 28400 | 2.06 | EPA 4603715 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218411771 | 22.00 | 8.50 | 28400 | 2.06 | EPA 4603723 → |
EVM5X60M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 218411755 | 22.00 | 8.50 | 28400 | 2.06 | EPA 4603739 → |
EVM5X60M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218411747 | 22.00 | 8.50 | 28400 | 2.06 | EPA 4603747 → |
EVM5X60M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 218411731 | 22.00 | 8.50 | 28400 | 2.06 | EPA 4603763 → |
EVM5X60M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218411723 | 22.00 | 8.50 | 28400 | 2.06 | EPA 4603771 → |
EVM5X60M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218411699 | 22.00 | 8.50 | 28400 | 2.06 | EPA 4603795 → |
EVM5X60M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 218411683 | 22.00 | 8.50 | 28400 | 2.04 | EPA 4603811 → |
EVM5X60M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218411675 | 22.00 | 8.50 | 28400 | 2.04 | EPA 4603819 → |
EVM5X60M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218411667 | 22.00 | 8.50 | 28400 | 2.04 | EPA 4603827 → |
EVM5X60M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218411651 | 22.00 | 8.50 | 28600 | 2.04 | EPA 4603843 → |
EVM5X60M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218411619 | 22.00 | 8.50 | 28600 | 2.04 | EPA 4603875 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →