B5H3V24*K*AAA*
SoftSound 23 VS Heat Pump · source records, page 2
419 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H3V24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 419 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–23 | 419 / 419 |
| EER2 · BTU/Wh | 10.5–14 | 419 / 419 |
| HSPF2 · BTU/Wh | 8.5–10.5 | 419 / 419 |
| Cooling capacity · BTU/h | 21,600–23,800 | 419 / 419 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,800–28,200 | 419 / 419 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,000–26,400 | 419 / 419 |
| Heating capacity at 5°F / −15°C · BTU/h | 19,100–23,000 | 419 / 419 |
| COP at 5°F / −15°C | 1.84–2.1 | 419 / 419 |
| Equipment / loop type | HP - Split System | 419 / 419 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 419 / 419 |
| Compressor staging | Continuously variable | 419 / 419 |
| Connected capability | No | 419 / 419 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X38M17A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218408923 | 22.50 | 9.50 | 22400 | 2.04 | EPA 4602571 → |
EVD5X37M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218408835 | 22.50 | 9.50 | 22200 | 2.08 | EPA 4602659 → |
EVD5X31M17A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218408547 | 22.50 | 9.50 | 22400 | 2.06 | EPA 4602947 → |
EVD5X31M17A*+WALLCON+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 218408531 | 22.50 | 9.50 | 22400 | 2.06 | EPA 4602963 → |
EVD5X31M17A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218408515 | 22.50 | 9.50 | 22400 | 2.06 | EPA 4602979 → |
EVD5X31M17A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218408507 | 22.50 | 9.50 | 22400 | 2.06 | EPA 4602987 → |
EVM5X44M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218408115 | 22.50 | 9.50 | 22400 | 2.06 | EPA 4603379 → |
EVM5X44M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 218408099 | 22.50 | 9.50 | 22400 | 2.06 | EPA 4603395 → |
EVM5X44M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218408091 | 22.50 | 9.50 | 22400 | 2.06 | EPA 4603403 → |
EVM5X44M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 218408075 | 22.50 | 9.50 | 22400 | 2.06 | EPA 4603419 → |
EVM5X44M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 218408059 | 22.50 | 9.50 | 22400 | 2.06 | EPA 4603435 → |
EVM5X44M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218408043 | 22.50 | 9.50 | 22400 | 2.04 | EPA 4603451 → |
EVM5X43M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218407955 | 22.50 | 9.50 | 22200 | 2.08 | EPA 4603539 → |
EVM5X43M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218407947 | 22.50 | 9.50 | 22200 | 2.08 | EPA 4603547 → |
EVM5X36M17A*+WALLCON+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 218407771 | 22.00 | 9.00 | 22400 | 1.98 | EPA 4599851 → |
EVM5X36M17A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218407755 | 22.00 | 9.50 | 22200 | 2.08 | EPA 4599867 → |
EVM5X36M17A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218407747 | 22.00 | 9.50 | 22200 | 2.10 | EPA 4599875 → |
EVM5X32M17A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218407739 | 22.00 | 9.50 | 22600 | 2.04 | EPA 4599883 → |
EVM5X32M17A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 218407691 | 22.00 | 9.50 | 22600 | 2.04 | EPA 4599931 → |
EVM5X32M17A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 218407683 | 22.00 | 9.50 | 22400 | 2.06 | EPA 4599939 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →