Heating performance & equipment details
Ranges include the 419 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–23 | 419 / 419 |
| EER2 · BTU/Wh | 10.5–14 | 419 / 419 |
| HSPF2 · BTU/Wh | 8.5–10.5 | 419 / 419 |
| Cooling capacity · BTU/h | 21,600–23,800 | 419 / 419 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,800–28,200 | 419 / 419 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,000–26,400 | 419 / 419 |
| Heating capacity at 5°F / −15°C · BTU/h | 19,100–23,000 | 419 / 419 |
| COP at 5°F / −15°C | 1.84–2.1 | 419 / 419 |
| Equipment / loop type | HP - Split System | 419 / 419 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 419 / 419 |
| Compressor staging | Continuously variable | 419 / 419 |
| Connected capability | No | 419 / 419 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X24M17A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 218408195 | 20.50 | 9.00 | 22200 | 2.02 | EPA 4603299 → |
EVD5X24M17A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 218408187 | 20.50 | 9.00 | 22200 | 2.02 | EPA 4603307 → |
EVD5X24M17A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 218408171 | 20.50 | 9.00 | 22000 | 2.02 | EPA 4603323 → |
EVD5X24M17A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 218408155 | 20.50 | 9.00 | 22200 | 2.02 | EPA 4603339 → |
EVD5X24M14A*+WALLCON+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 218408123 | 20.50 | 9.00 | 22000 | 2.04 | EPA 4603371 → |
EA*5X37M17A*+WALLCON+ furnace: *97CTN0601716A*Cold climate designationAHRI reference: 218406451 | 20.00 | 9.50 | 19600 | 1.96 | EPA 4599726 → |
EVM5X36M17A*+WALLCON+ furnace: *96CTN0401410B*Cold climate designationAHRI reference: 218407819 | 20.00 | 9.00 | 22800 | 1.98 | EPA 4599803 → |
EVM5X25M17A*+WALLCON+ furnace: *96CTN0401410B*Cold climate designationAHRI reference: 218407379 | 20.00 | 9.00 | 22800 | 1.98 | EPA 4600243 → |
EVM5X24M17A*+WALLCON+ furnace: *97CTN0601716A*Cold climate designationAHRI reference: 218407291 | 20.00 | 9.00 | 22200 | 2.02 | EPA 4600331 → |
ESH5X42M12A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 218407163 | 20.00 | 9.50 | 19400 | 1.96 | EPA 4600459 → |
ESH5X42M12A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218407115 | 20.00 | 9.50 | 19400 | 1.98 | EPA 4600507 → |
ESH5X42M12A*+WALLCON+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 218407099 | 20.00 | 9.50 | 19400 | 1.96 | EPA 4600523 → |
ESH5X42M12A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218407083 | 20.00 | 9.50 | 19300 | 1.98 | EPA 4600539 → |
ESH5X42M12A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218407075 | 20.00 | 9.50 | 19300 | 1.98 | EPA 4600547 → |
ESH5X36M12A*+WALLCON+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 218406987 | 20.00 | 9.50 | 19500 | 1.96 | EPA 4600635 → |
ESH5X36M12A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218406971 | 20.00 | 9.50 | 19500 | 1.96 | EPA 4600651 → |
ESH5X36M12A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218406963 | 20.00 | 9.50 | 19400 | 1.98 | EPA 4600659 → |
ESH5X30M12A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218406859 | 20.00 | 9.50 | 19600 | 1.98 | EPA 4600763 → |
ESH5X30M12A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218406851 | 20.00 | 9.50 | 19600 | 1.98 | EPA 4600771 → |
EA*5X42M21A*+WALLCON+ furnace: *97CTN0601716A*Cold climate designationAHRI reference: 218406643 | 20.00 | 9.50 | 19700 | 1.96 | EPA 4600979 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.