B5H0V48*K*AAA*
SoftSound 20 VS Heat Pump · source records, page 3
327 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 327 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 327 / 327 |
| EER2 · BTU/Wh | 9–10.5 | 327 / 327 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 327 / 327 |
| Cooling capacity · BTU/h | 43,500–49,000 | 327 / 327 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 327 / 327 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 327 / 327 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 327 / 327 |
| COP at 5°F / −15°C | 1.92–2.2 | 327 / 327 |
| Equipment / loop type | HP - Split System | 327 / 327 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 327 / 327 |
| Compressor staging | Continuously variable | 327 / 327 |
| Connected capability | No | 327 / 327 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X60M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218173435 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4581003 → |
EVD5X60M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218173426 | 19.00 | 9.00 | 36600 | 2.12 | EPA 4581012 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218173417 | 19.00 | 9.50 | 36600 | 2.10 | EPA 4581021 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218173414 | 19.00 | 9.50 | 36600 | 2.12 | EPA 4581024 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218173411 | 19.00 | 9.00 | 36800 | 1.98 | EPA 4581027 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218173408 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4581030 → |
EVD5X49M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 218173399 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4581039 → |
EVD5X49M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218173396 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4581042 → |
EVD5X49M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 218173393 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4581045 → |
EVD5X49M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218173389 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4581048 → |
EVD5X49M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218173386 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4581051 → |
EVD5X49M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218173380 | 19.00 | 9.00 | 36400 | 2.02 | EPA 4581057 → |
EVD5X49M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 218173377 | 19.00 | 9.00 | 36400 | 2.00 | EPA 4581060 → |
EVD5X49M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218173374 | 19.00 | 9.00 | 36400 | 2.00 | EPA 4581063 → |
EVD5X49M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218173371 | 19.00 | 9.00 | 36400 | 2.00 | EPA 4581066 → |
EVD5X49M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218173368 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4581069 → |
EVD5X48M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 218173350 | 19.00 | 9.00 | 36200 | 2.00 | EPA 4581087 → |
EVD5X48M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218173347 | 19.00 | 9.00 | 36200 | 2.00 | EPA 4581090 → |
EVD5X48M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218173344 | 19.00 | 9.00 | 36200 | 2.00 | EPA 4581093 → |
EVM5X61M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218173308 | 19.00 | 9.50 | 36800 | 2.12 | EPA 4581129 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →