Comfort-Aire / AIR-SOURCE HEAT PUMP

HSA1960V1-**A

HSA19 SERIES · HSA19 Series

41 published source records · source checked Sep 21, 2026

SEER2 range16.5–18BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for HSA1960V1-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 41 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16.5–1841 / 41
EER2 · BTU/Wh11–11.741 / 41
HSPF2 · BTU/Wh7.8–8.241 / 41
Cooling capacity · BTU/h46,000–48,00041 / 41
Heating capacity at 47°F / 8.3°C · BTU/h45,500–48,00041 / 41
Heating capacity at 17°F / −8.3°C · BTU/h27,800–30,20041 / 41
Heating capacity at 5°F / −15°C · BTU/h21,800–29,60041 / 41
COP at 5°F / −15°C1.8–2.0641 / 41
Equipment / loop typeHP - Split System41 / 41
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)41 / 41
Compressor stagingContinuously variable41 / 41
Connected capabilityNo41 / 41

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7E[C,U]50/60CX-**+TDR+ furnace: GUH80C110C5MPAHRI reference: 21750451218.008.20236001.88EPA 4468567
7E[C,U]50/60CX-**+TDR+ furnace: GUH92C090C4MPAHRI reference: 21750451318.008.20234001.86EPA 4468568
7E[C,U]50/60CX-**+TDR+ furnace: GUH96C090C4MPAHRI reference: 21750451818.008.20234001.86EPA 4468572
7E[C,U]48CX-**+TDR+ furnace: GUH80C110C5MPAHRI reference: 21750452918.007.80222001.82EPA 4468681
7E[C,U]48CX-**+TDR+ furnace: GUH92C090C4MPAHRI reference: 21750453118.007.80220001.80EPA 4468683
7E[C,U]48CX-**+TDR+ furnace: GUH92C110C4MPAHRI reference: 21750453218.007.80220001.82EPA 4468684
7E[C,U]48CX-**+TDR+ furnace: GUH96C090C4MPAHRI reference: 21750453518.007.80220001.82EPA 4468687
7E[C,U]48BX-**+TDR+ furnace: GUH80C090B4MPAHRI reference: 21750455418.007.80220001.82EPA 4468705
7E[C,U]50/60CX-**+TDR+ furnace: GUH80C090B4MPAHRI reference: 21750460318.008.20234001.88EPA 4468731
7E[C,U]48CX-**+TDR+ furnace: GUH80C090B4MPAHRI reference: 21750460818.007.80220001.82EPA 4468737
7ED50/60CX-**+TDR+ furnace: GDD80C110C5MPAHRI reference: 21750462818.008.00288001.96EPA 4468758
7ED50/60CX-**+TDR+ furnace: GDD92C090C4MPAHRI reference: 21750463018.008.00294001.92EPA 4468759
7E[C,U]50/60CX-**+TDR+ furnace: GUH97T090C3MPAHRI reference: 21754748818.007.80232001.86EPA 4469852
7E[C,U]50/60CX-**+TDR+ furnace: GUH97T090C5MP*AHRI reference: 21754748918.007.80238001.86EPA 4469853
HMA48CX1*-**AHRI reference: 21766274418.007.80234002.06EPA 4512849
7E[C,U]50/60CX-**+TDR+ furnace: GUH80X100C5MPAHRI reference: 21750450917.508.20238001.84EPA 4468565
7E[C,U]50/60CX-**+TDR+ furnace: GUH92C110C4MPAHRI reference: 21750451517.508.20234001.88EPA 4468570
7E[C,U]50/60CX-**+TDR+ furnace: GUH92C110C5MPAHRI reference: 21750451717.508.20236001.86EPA 4468577
7E[C,U]50/60CX-**+TDR+ furnace: GUH97T110C5MPAHRI reference: 21750452217.508.00236001.88EPA 4468578
7E[C,U]48CX-**+TDR+ furnace: GUH80X100C5MPAHRI reference: 21750452717.507.80224001.80EPA 4468580

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.