Comfort-Aire / AIR-SOURCE HEAT PUMP

HRG1542S1R-**A

HRG15 SERIES · HRG15 Series · source records, page 2

30 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range7.8–8.3BTU/Wh
Cooling capacity40,000–41,500BTU/h

Each efficiency range summarizes published EPA records for HRG1542S1R-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 30 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.630 / 30
EER2 · BTU/Wh12.5–1330 / 30
HSPF2 · BTU/Wh7.8–8.330 / 30
Cooling capacity · BTU/h40,000–41,50030 / 30
Heating capacity at 47°F / 8.3°C · BTU/h37,600–42,00030 / 30
Heating capacity at 17°F / −8.3°C · BTU/h25,200–27,60030 / 30
Heating capacity at 5°F / −15°C · BTU/h19,600–22,00030 / 30
COP at 5°F / −15°C2.02–2.1430 / 30
Equipment / loop typeHP - Split System30 / 30
Refrigerant / source-reported GWPR-410A (GWP:2088)30 / 30
Compressor stagingSingle stage30 / 30
Connected capabilityNo30 / 30

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC48CX-0*+TDR+ furnace: GUH92C090C4MAHRI reference: 21471313815.207.80196002.06EPA 3486511
7EC49CX-0*+TDR+ furnace: GUH92C090C4MAHRI reference: 21471315115.207.80198002.08EPA 3486791
7EC49CX-0*+TDR+ furnace: GUH92C110C5MAHRI reference: 21471315315.207.80199002.08EPA 3486797
7EC49CX-0*+TDR+ furnace: GUH96C090C4MAHRI reference: 21471315415.207.80199002.08EPA 3486952
7EH48BX-0*+TDR+ furnace: GUH80C090B4MAHRI reference: 21471310615.207.80202002.02EPA 3487158
7EH48CX-0*+TDR+ furnace: GUH80C110C5MAHRI reference: 21471311215.207.80202002.04EPA 3487161
7ED48CX-0*+TDR+ furnace: GDD96C110C5MAHRI reference: 21471312615.208.20220002.12EPA 3487173
7EC49CX-0*+TDR+ furnace: GUH96C110C5MAHRI reference: 21471315515.207.80199002.08EPA 3491610
7EC48CX-0*+TDR+ furnace: GUH80C090C5MAHRI reference: 21471313515.207.80200002.08EPA 3491625
EAH1P48B+TDR+ furnace: GUH80C090B4MAHRI reference: 21251753615.207.80202002.02EPA 3493307

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →