Comfort-Aire / AIR-SOURCE HEAT PUMP

HRG1536S1R-**A

HRG15 SERIES · HRG15 Series · source records, page 4

122 published source records · source checked Sep 21, 2026

SEER2 range15.4–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity35,000–36,000BTU/h

Each efficiency range summarizes published EPA records for HRG1536S1R-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 122 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–16.8122 / 122
EER2 · BTU/Wh12.5–13.5122 / 122
HSPF2 · BTU/Wh7.8–8.7122 / 122
Cooling capacity · BTU/h35,000–36,000122 / 122
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000122 / 122
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800122 / 122
Heating capacity at 5°F / −15°C · BTU/h16,800–19,100122 / 122
COP at 5°F / −15°C2.08–2.34122 / 122
Equipment / loop typeHP - Split System122 / 122
Refrigerant / source-reported GWPR-410A (GWP:2088)122 / 122
Compressor stagingSingle stage122 / 122
Connected capabilityNo122 / 122

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC50/60CX-0*+TDR+ furnace: GUH80C110C5MAHRI reference: 21471307416.207.80173002.12EPA 3487177
7EC50/60CX-0*+TDR+ furnace: GUH92C090C4MAHRI reference: 21471307616.207.80172002.14EPA 3487180
7EC50/60CX-0*+TDR+ furnace: GUH92C110C4MAHRI reference: 21471307716.207.80170002.12EPA 3487182
7EC50/60CX-0*+TDR+ furnace: GUH96C090C4MAHRI reference: 21471307916.207.80172002.12EPA 3487186
7EC50/60CX-0*+TDR+ furnace: GUH96C110C5MAHRI reference: 21471308016.207.80172002.12EPA 3487187
EA(C;U)1P36A+TDR+TXV+ furnace: GUH80C070A3MAHRI reference: 21033037416.007.80172002.12EPA 2456237
EA(C;U)1P50/60C+TDR+TXV+ furnace: GUH92C110C5MAHRI reference: 21033038316.007.80172002.12EPA 2456242
EA(C;U)1P36A+TDR+TXV+ furnace: GUH80C045A3MAHRI reference: 21033037316.007.80170002.12EPA 2457759
EA(C;U)1P50/60C+TDR+TXV+ furnace: GUH97M090C4MAHRI reference: 21033039116.007.80174002.12EPA 2457991
EA(C;U)1P36A+TDR+TXV+ furnace: GUH92C070B3MAHRI reference: 21033037616.007.80171002.14EPA 2458006
EA(C;U)1P50/60C+TDR+TXV+ furnace: GUH92C090C3MAHRI reference: 21033039216.007.80172002.10EPA 2458885
EA(C;U)1P50/60C+TDR+TXV+ furnace: GUH97M090C3MAHRI reference: 21033039416.007.80173002.12EPA 2459135
EA(C;U)1P50/60C+TDR+TXV+ furnace: GUH97M110C5MAHRI reference: 21033039016.007.80174002.12EPA 2459642
EAD4X-30/36C+TDR+ furnace: GDD96C090C4MAHRI reference: 21326549016.008.00187002.16EPA 2839908
7ED30/36CX-0*+TDR+ furnace: GDD96C090C4MAHRI reference: 21471303516.008.00187002.16EPA 3486404
7EH42BX-0*+TDR+ furnace: GUH92C070B3MAHRI reference: 21471298916.008.10183002.22EPA 3486711
7EH42CX-0*+TDR+ furnace: GUH80X100C5MAHRI reference: 21471299316.008.00182002.18EPA 3486716
7EH42BX-0*+TDR+ furnace: GUH80C070B3MAHRI reference: 21471298616.008.10184002.24EPA 3486821
7EH51CX-0*+TDR+ furnace: GUH97M090C5MAHRI reference: 21471302616.008.10178002.16EPA 3486832
7EH48BX-0*+TDR+ furnace: GUH92C070B3MAHRI reference: 21471301116.007.80172002.20EPA 3486911

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →