Comfort-Aire / AIR-SOURCE HEAT PUMP

HRG1536S1R-**A

HRG15 SERIES · HRG15 Series · source records, page 2

122 published source records · source checked Sep 21, 2026

SEER2 range15.4–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity35,000–36,000BTU/h

Each efficiency range summarizes published EPA records for HRG1536S1R-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 122 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–16.8122 / 122
EER2 · BTU/Wh12.5–13.5122 / 122
HSPF2 · BTU/Wh7.8–8.7122 / 122
Cooling capacity · BTU/h35,000–36,000122 / 122
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000122 / 122
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800122 / 122
Heating capacity at 5°F / −15°C · BTU/h16,800–19,100122 / 122
COP at 5°F / −15°C2.08–2.34122 / 122
Equipment / loop typeHP - Split System122 / 122
Refrigerant / source-reported GWPR-410A (GWP:2088)122 / 122
Compressor stagingSingle stage122 / 122
Connected capabilityNo122 / 122

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC48CX-0*+TDR+ furnace: GUH97M110C5MAHRI reference: 21471307016.407.80172002.14EPA 3487001 →
7EC50/60CX-0*+TDR+ furnace: GUH80C090C5MAHRI reference: 21471307316.407.80170002.12EPA 3487004 →
7EH42CX-0*+TDR+ furnace: GUH80C090C5MAHRI reference: 21471299416.408.00179002.20EPA 3487015 →
7EH42CX-0*+TDR+ furnace: GUH80C110C5MAHRI reference: 21471299516.408.10180002.20EPA 3487052 →
7EH51CX-0*+TDR+ furnace: GUH92C110C4MAHRI reference: 21471302016.407.80174002.18EPA 3487069 →
7EH51CX-0*+TDR+ furnace: GUH92C110C5MAHRI reference: 21471302116.408.00173002.20EPA 3487070 →
7EH51CX-0*+TDR+ furnace: GUH96C110C5MAHRI reference: 21471302316.408.00175002.22EPA 3487072 →
7EH42CX-0*+TDR+ furnace: GUH92C090C4MAHRI reference: 21471299716.408.00179002.20EPA 3487082 →
7EH42CX-0*+TDR+ furnace: GUH97M090C4MAHRI reference: 21471300316.408.00180002.20EPA 3487084 →
7EH42CX-0*+TDR+ furnace: GUH92C110C5MAHRI reference: 21471299916.408.00179002.18EPA 3487130 →
7EH42CX-0*+TDR+ furnace: GUH96C090C4MAHRI reference: 21471300016.408.00181002.20EPA 3487153 →
HCG42V1PAHRI reference: 21117442216.208.10174002.22EPA 2454742 →
EA(C;U)1P50/60C+TDR+TXV+ furnace: GUH96C110C5MAHRI reference: 21033041916.207.80172002.12EPA 2456234 →
EA(C;U)1P50/60C+TDR+TXV+ furnace: GUH80C110C5MAHRI reference: 21033038216.207.80173002.12EPA 2456542 →
EA(C;U)1P36A+TDR+TXV+ furnace: GUH80C070B3MAHRI reference: 21033037716.207.80172002.14EPA 2457334 →
EA(C;U)1P50/60C+TDR+TXV+ furnace: GUH92C110C4MAHRI reference: 21033038516.207.80170002.12EPA 2458889 →
EA(C;U)1P50/60C+TDR+TXV+ furnace: GUH92C090C4MAHRI reference: 21033038416.207.80172002.14EPA 2459178 →
EA(C;U)1P50/60C+TDR+TXV+ furnace: GUH96C090C4MAHRI reference: 21033038616.207.80172002.12EPA 2459394 →
EAD4X-48C+TDR+ furnace: GDD92C090C4MAHRI reference: 21326549316.208.70191002.32EPA 2839912 →
EAD4X-48C+TDR+ furnace: GDD96C090C4MAHRI reference: 21326549416.208.70191002.34EPA 2839913 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →