XH960E2C11
LX SERIES · source records, page 9
197 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH960E2C11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 197 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 19–22 | 197 / 197 |
| EER2 · BTU/Wh | 9–12 | 197 / 197 |
| HSPF2 · BTU/Wh | 8.5–9 | 197 / 197 |
| Cooling capacity · BTU/h | 47,000–56,000 | 197 / 197 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–59,000 | 197 / 197 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 34,000–47,500 | 197 / 197 |
| Heating capacity at 5°F / −15°C · BTU/h | 43,500–45,000 | 197 / 197 |
| COP at 5°F / −15°C | 1.98–2 | 197 / 197 |
| Equipment / loop type | HP - Split System | 197 / 197 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 197 / 197 |
| Compressor staging | Continuously variable | 197 / 197 |
| Connected capability | No | 197 / 197 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60C5CGS2+CC+ furnace: TM8V100C20MP12Cold climate designationAHRI reference: 218586277 | 20.00 | 8.50 | 45000 | 2.00 | EPA 4650703 → |
CTF60C5CGS2+CC+ furnace: TM8V120C20MP12Cold climate designationAHRI reference: 218586261 | 20.00 | 8.50 | 45000 | 2.00 | EPA 4650711 → |
CTF60C5CHS1+CC+ furnace: CPLC120C20MP13Cold climate designationAHRI reference: 218027617 | 19.00 | 8.50 | 44000 | 2.00 | EPA 4518866 → |
CTF60C5CHS1+CC+ furnace: CPLC100C20MP13Cold climate designationAHRI reference: 218027615 | 19.00 | 8.50 | 44000 | 2.00 | EPA 4518868 → |
CTF60C5CHS1+CC+ furnace: TPLC120C20MP13Cold climate designationAHRI reference: 218027610 | 19.00 | 8.50 | 44000 | 2.00 | EPA 4518873 → |
CTF60C5CHS1+CC+ furnace: TPLC100C20MP13Cold climate designationAHRI reference: 218027605 | 19.00 | 8.50 | 44000 | 2.00 | EPA 4518878 → |
CTF60C5CHS1+CC+ furnace: TMLV120C20MP12Cold climate designationAHRI reference: 218027600 | 19.00 | 8.50 | 44000 | 2.00 | EPA 4518883 → |
CTF60C5CHS1+CC+ furnace: TM8V100C20MP12Cold climate designationAHRI reference: 218027595 | 19.00 | 8.50 | 44000 | 2.00 | EPA 4518888 → |
CTF60C5CHS1+CC+ furnace: TM8V120C20MP12Cold climate designationAHRI reference: 218027590 | 19.00 | 8.50 | 44000 | 2.00 | EPA 4518893 → |
CTF60D5CHS1+CC+ furnace: CP9C120D20MP13Cold climate designationAHRI reference: 218027464 | 19.00 | 8.50 | 44500 | 2.00 | EPA 4518953 → |
CTF60D5CHS1+CC+ furnace: TP9C120D20MP13Cold climate designationAHRI reference: 218027459 | 19.00 | 8.50 | 44500 | 2.00 | EPA 4518958 → |
CTF60D5CHS1+CC+ furnace: TM9V120D20MP12Cold climate designationAHRI reference: 218027454 | 19.00 | 8.50 | 44500 | 2.00 | EPA 4518963 → |
CTM60D5CHS1+CC+ furnace: CP9C120D20MP13Cold climate designationAHRI reference: 218027452 | 19.00 | 8.50 | 44500 | 2.00 | EPA 4518965 → |
CTM60D5CHS1+CC+ furnace: TP9C120D20MP13Cold climate designationAHRI reference: 218027447 | 19.00 | 8.50 | 44500 | 2.00 | EPA 4518970 → |
CTM60D5CHS1+CC+ furnace: TM9V120D20MP12Cold climate designationAHRI reference: 218027442 | 19.00 | 8.50 | 44500 | 2.00 | EPA 4518975 → |
CTM60C5CHS1+CC+ furnace: CP9C100C20MP13Cold climate designationAHRI reference: 218027302 | 19.00 | 8.50 | 45000 | 2.00 | EPA 4519021 → |
CTM60C5CHS1+CC+ furnace: TP9C100C20MP13Cold climate designationAHRI reference: 218027297 | 19.00 | 8.50 | 45000 | 2.00 | EPA 4519026 → |
CTM60C5CHS1+CC+ furnace: TM9V100C20MP12Cold climate designationAHRI reference: 218027292 | 19.00 | 8.50 | 45000 | 2.00 | EPA 4519031 → |
JHC60C5CH2SS1+CCCold climate designationAHRI reference: 218027283 | 19.00 | 8.50 | 43500 | 2.00 | EPA 4519040 → |
CTF60C5CHS1+CC+ furnace: Z9VT100C20SMPC1Cold climate designationAHRI reference: 218027172 | 19.00 | 8.50 | 44000 | 2.00 | EPA 4519090 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →