Coleman / AIR-SOURCE HEAT PUMP

XH960E2C11

LX SERIES

197 published source records · source checked Sep 21, 2026

SEER2 range19–22BTU/Wh
HSPF2 range8.5–9BTU/Wh
Cooling capacity47,000–56,000BTU/h

Each efficiency range summarizes published EPA records for XH960E2C11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 197 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh19–22197 / 197
EER2 · BTU/Wh9–12197 / 197
HSPF2 · BTU/Wh8.5–9197 / 197
Cooling capacity · BTU/h47,000–56,000197 / 197
Heating capacity at 47°F / 8.3°C · BTU/h46,500–59,000197 / 197
Heating capacity at 17°F / −8.3°C · BTU/h34,000–47,500197 / 197
Heating capacity at 5°F / −15°C · BTU/h43,500–45,000197 / 197
COP at 5°F / −15°C1.98–2197 / 197
Equipment / loop typeHP - Split System197 / 197
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)197 / 197
Compressor stagingContinuously variable197 / 197
Connected capabilityNo197 / 197

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60C5CGS1+JMC17C2SN1+CCCold climate designationAHRI reference: 21802773422.009.00445002.00EPA 4518789 →
CTF60C5CGS1+JMC17C2SN1+CCCold climate designationAHRI reference: 21802724522.008.50445002.00EPA 4519045 →
CTM60C5CGS2+JMC17C2SN1+CCCold climate designationAHRI reference: 21858812022.009.00445002.00EPA 4649896 →
CTF60C5CGS2+JMC17C2SN1+CCCold climate designationAHRI reference: 21858715822.008.50445002.00EPA 4650255 →
CTM60C5CGS1+CC+ furnace: Z8VT120C20SMPC1Cold climate designationAHRI reference: 21802766121.008.50450002.00EPA 4518822 →
CTM60C5CGS1+CC+ furnace: Z8VT100C16SMPC1Cold climate designationAHRI reference: 21802765721.008.50450002.00EPA 4518826 →
CTF60C5CGS1+CC+ furnace: Z9VT100C16SMPC1AHRI reference: 21802762421.008.50450002.00EPA 4518859 →
CTF60D5CGS1+JMC20D2SN1+CCCold climate designationAHRI reference: 21802756321.008.50445002.00EPA 4518902 →
CTM60C5CGS1+CC+ furnace: Z9VT100C20SMPC1AHRI reference: 21802749921.008.50450002.00EPA 4518918 →
CTM60C5CGS1+JMC16C2SN1+CCCold climate designationAHRI reference: 21802739621.008.50445002.00EPA 4518980 →
JSC48C5CG2SS1+CCCold climate designationAHRI reference: 21802739121.008.50450002.00EPA 4518985 →
JHC48C5CG2SS1+CCCold climate designationAHRI reference: 21802738621.008.50450002.00EPA 4518990 →
CTM60D5CGS1+CC+ furnace: Z9VT120D20SMPC1AHRI reference: 21802738221.008.50450002.00EPA 4518994 →
CTM60C5CGS1+CC+ furnace: Z8VT080C16SMPC1Cold climate designationAHRI reference: 21802732021.008.50450002.00EPA 4519003 →
CTF60C5CGS1+CC+ furnace: Z8VT100C16SMPC1Cold climate designationAHRI reference: 21802731621.008.50450002.00EPA 4519007 →
CTM60C5CGS1+CC+ furnace: CP9C100C16MP13Cold climate designationAHRI reference: 21802724321.008.50450001.98EPA 4519047 →
CTM60C5CGS1+CC+ furnace: TP9C100C16MP13Cold climate designationAHRI reference: 21802723821.008.50450001.98EPA 4519052 →
CTM60C5CGS1+CC+ furnace: TM9V100C16MP12Cold climate designationAHRI reference: 21802723321.008.50450001.98EPA 4519057 →
CTF60D5CGS1+CC+ furnace: Z9VT120D20SMPC1AHRI reference: 21802722921.008.50450002.00EPA 4519061 →
CTM60C5CGS1+CC+ furnace: Z9VT080C16SMPC1AHRI reference: 21802719221.008.50450002.00EPA 4519070 →