Coleman / AIR-SOURCE HEAT PUMP

XH648E2S11

LX SERIES · source records, page 25

554 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,000–49,000BTU/h

Each efficiency range summarizes published EPA records for XH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 554 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16554 / 554
EER2 · BTU/Wh11.7–12554 / 554
HSPF2 · BTU/Wh7.8–8.1554 / 554
Cooling capacity · BTU/h45,000–49,000554 / 554
Heating capacity at 47°F / 8.3°C · BTU/h46,000–50,000554 / 554
Heating capacity at 17°F / −8.3°C · BTU/h31,800–34,000554 / 554
Heating capacity at 5°F / −15°C · BTU/h25,000–27,800554 / 554
COP at 5°F / −15°C2–2.4554 / 554
Equipment / loop typeHP - Split System554 / 554
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)554 / 554
Compressor stagingTwo-stage554 / 554
Connected capabilityNo554 / 554

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60C5XGS1+TXV+ furnace: TM9V100C20MP12AHRI reference: 21799411715.208.00260002.00EPA 4571006 →
CTF60C5CGS1+ furnace: CP9C100C20MP13AHRI reference: 21799411515.208.00260002.00EPA 4571008 →
CTF60C5CGS1+ furnace: TP9C100C20MP13AHRI reference: 21799411015.208.00260002.00EPA 4571013 →
CTF60C5CGS1+ furnace: TM9V100C20MP12AHRI reference: 21799410515.208.00260002.00EPA 4571018 →
CTM60C5CGS1+ furnace: CP9C100C16MP13AHRI reference: 21799410315.208.00260002.00EPA 4571020 →
CTM60C5CGS1+ furnace: TP9C100C16MP13AHRI reference: 21799409815.208.00260002.00EPA 4571025 →
CTM60C5CGS1+ furnace: TM9V100C16MP12AHRI reference: 21799409315.208.00260002.00EPA 4571030 →
CTM60C5CGS1+ furnace: CP9C080C16MP13AHRI reference: 21799409115.208.00260002.00EPA 4571032 →
CTM60C5CGS1+ furnace: TP9C080C16MP13AHRI reference: 21799408615.208.00260002.00EPA 4571037 →
CTM60C5CGS1+ furnace: TM9V080C16MP12AHRI reference: 21799408115.208.00260002.00EPA 4571042 →
CTU60C5XGS1+TXV+ furnace: CP9C080C16MP13AHRI reference: 21799407915.208.00260002.00EPA 4571044 →
CTU60C5XGS1+TXV+ furnace: TP9C080C16MP13AHRI reference: 21799407415.208.00260002.00EPA 4571049 →
CTU60C5XGS1+TXV+ furnace: TM9V080C16MP12AHRI reference: 21799406915.208.00260002.00EPA 4571054 →
CTF60C5CGS1+ furnace: CP9C080C16MP13AHRI reference: 21799406715.208.00260002.00EPA 4571056 →
CTF60C5CGS1+ furnace: TP9C080C16MP13AHRI reference: 21799406215.208.00260002.00EPA 4571061 →
CTF60C5CGS1+ furnace: TM9V080C16MP12AHRI reference: 21799405715.208.00260002.00EPA 4571066 →
CTM60D5CGS1+ furnace: Z9ES120D20SMPS1AHRI reference: 21702270415.208.10276002.24EPA 4571217 →
CTM60C5CGS1+ furnace: Z9ES100C16SMPS1AHRI reference: 21702266315.208.10272002.24EPA 4571219 →
CTF60D5CGS1+ furnace: Z9ES120D20SMPS1AHRI reference: 21701943315.208.10274002.26EPA 4571431 →
CTU60D5XGS1+TXV+ furnace: Z9ES120D20SMPS1AHRI reference: 21701943115.208.10274002.26EPA 4571432 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →