Coleman / AIR-SOURCE HEAT PUMP

XH648E2S11

LX SERIES · source records, page 21

554 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,000–49,000BTU/h

Each efficiency range summarizes published EPA records for XH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 554 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16554 / 554
EER2 · BTU/Wh11.7–12554 / 554
HSPF2 · BTU/Wh7.8–8.1554 / 554
Cooling capacity · BTU/h45,000–49,000554 / 554
Heating capacity at 47°F / 8.3°C · BTU/h46,000–50,000554 / 554
Heating capacity at 17°F / −8.3°C · BTU/h31,800–34,000554 / 554
Heating capacity at 5°F / −15°C · BTU/h25,000–27,800554 / 554
COP at 5°F / −15°C2–2.4554 / 554
Equipment / loop typeHP - Split System554 / 554
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)554 / 554
Compressor stagingTwo-stage554 / 554
Connected capabilityNo554 / 554

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CGS2+ furnace: Z8ES080C16LMPS1AHRI reference: 21852942116.008.10270002.26EPA 4649409 →
CTF60C5CGS2+ furnace: Z8ES080C16SMPS1AHRI reference: 21852941716.008.10270002.26EPA 4649413 →
CTU60C5XGS2+TXV+ furnace: Z8ET100C20LMPS1AHRI reference: 21852941316.008.10276002.26EPA 4649417 →
CTF60C5CGS2+ furnace: Z8ET100C20LMPS1AHRI reference: 21852940916.008.10276002.26EPA 4649421 →
CTU60C5XGS2+TXV+ furnace: Z8ET100C16LMPS1AHRI reference: 21852940516.008.10274002.24EPA 4649425 →
CTF60C5CGS2+ furnace: Z8ET100C16LMPS1AHRI reference: 21852940116.008.10274002.24EPA 4649429 →
CTU60C5XGS2+TXV+ furnace: Z8ET080C16LMPS1AHRI reference: 21852939716.008.10270002.26EPA 4649433 →
CTF60C5CGS2+ furnace: Z8ET080C16LMPS1AHRI reference: 21852939316.008.10270002.26EPA 4649437 →
CTU60C5XGS2+TXV+ furnace: Z9ET100C20SMPS1AHRI reference: 21852938916.008.10274002.22EPA 4649441 →
CTF60C5CGS2+ furnace: Z9ET100C20SMPS1AHRI reference: 21852938516.008.10274002.22EPA 4649445 →
CTU60C5XGS2+TXV+ furnace: Z9ES100C20SMPS1AHRI reference: 21852937916.008.10274002.22EPA 4649451 →
CTF60C5CGS2+ furnace: Z9ES100C20SMPS1AHRI reference: 21852937316.008.10274002.22EPA 4649457 →
CTU60C5XGS2+TXV+ furnace: Z8ES080C20LMPS1AHRI reference: 21852936716.008.10276002.26EPA 4649463 →
CTU60C5XGS2+TXV+ furnace: Z8ES080C20SMPS1AHRI reference: 21852936316.008.10276002.26EPA 4649467 →
CTF60C5CGS2+ furnace: Z8ES080C20LMPS1AHRI reference: 21852935716.008.10276002.26EPA 4649473 →
CTF60C5CGS2+ furnace: Z8ES080C20SMPS1AHRI reference: 21852935316.008.10276002.26EPA 4649477 →
CTU60C5XGS2+TXV+ furnace: Z8ES100C16LMPS1AHRI reference: 21852933516.008.10276002.26EPA 4649495 →
CTU60C5XGS2+TXV+ furnace: Z8ES100C16SMPS1AHRI reference: 21852933116.008.10276002.26EPA 4649499 →
CTF60C5CGS2+ furnace: Z8ES100C16LMPS1AHRI reference: 21852932516.008.10276002.26EPA 4649505 →
CTF60C5CGS2+ furnace: Z8ES100C16SMPS1AHRI reference: 21852932116.008.10276002.26EPA 4649509 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →