Coleman / AIR-SOURCE HEAT PUMP

XH648E2S11

LX SERIES · source records, page 19

554 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,000–49,000BTU/h

Each efficiency range summarizes published EPA records for XH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 554 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16554 / 554
EER2 · BTU/Wh11.7–12554 / 554
HSPF2 · BTU/Wh7.8–8.1554 / 554
Cooling capacity · BTU/h45,000–49,000554 / 554
Heating capacity at 47°F / 8.3°C · BTU/h46,000–50,000554 / 554
Heating capacity at 17°F / −8.3°C · BTU/h31,800–34,000554 / 554
Heating capacity at 5°F / −15°C · BTU/h25,000–27,800554 / 554
COP at 5°F / −15°C2–2.4554 / 554
Equipment / loop typeHP - Split System554 / 554
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)554 / 554
Compressor stagingTwo-stage554 / 554
Connected capabilityNo554 / 554

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CHS2+ furnace: TP9C100C20MP13AHRI reference: 21852960916.008.00260002.00EPA 4649221
CTF60C5CHS2+ furnace: TM9V100C20MP12AHRI reference: 21852960516.008.00260002.00EPA 4649225
CTF60C5CHS2+ furnace: CP9C100C16MP13AHRI reference: 21852960316.008.00260002.00EPA 4649227
CTF60C5CHS2+ furnace: TP9C100C16MP13AHRI reference: 21852959916.008.00260002.00EPA 4649231
CTF60C5CHS2+ furnace: TM9V100C16MP12AHRI reference: 21852959516.008.00260002.00EPA 4649235
CTF60C5CHS2+ furnace: Z8ET120C20LMPS1AHRI reference: 21852959116.008.10274002.32EPA 4649239
CTF60C5CHS2+ furnace: Z8ES080C16LMPS1AHRI reference: 21852958516.008.10268002.34EPA 4649245
CTF60C5CHS2+ furnace: Z8ES080C16SMPS1AHRI reference: 21852958116.008.10268002.34EPA 4649249
CTF60C5CHS2+ furnace: Z8ET100C16LMPS1AHRI reference: 21852957716.008.10266002.34EPA 4649253
CTF60C5CHS2+JMC17C2SN1AHRI reference: 21852957316.008.10270002.36EPA 4649257
CTF60C5CHS2+JMVT16CC2N1AHRI reference: 21852956916.008.10270002.36EPA 4649261
CTF60C5CHS2+JMC16C2SN1AHRI reference: 21852956516.008.10270002.36EPA 4649265
CTF60C5CHS2+ furnace: Z8ET100C20LMPS1AHRI reference: 21852956116.008.10274002.32EPA 4649269
CTF60C5CHS2+ furnace: Z9ES100C20SMPS1AHRI reference: 21852955516.008.10274002.30EPA 4649275
CTF60C5CHS2+ furnace: Z9ET100C16SMPS1AHRI reference: 21852955116.008.10276002.28EPA 4649279
CTF60C5CHS2+ furnace: Z9ET080C16SMPS1AHRI reference: 21852954716.007.80268002.30EPA 4649283
CTF60C5CHS2+ furnace: Z9ES080C16SMPS1AHRI reference: 21852954116.007.80268002.30EPA 4649289
CTF60C5CHS2+ furnace: Z8ET080C16LMPS1AHRI reference: 21852953716.008.10266002.34EPA 4649293
CTF60C5CHS2+ furnace: Z8ES120C16LMPS1AHRI reference: 21852953116.008.10272002.34EPA 4649299
CTF60C5CHS2+ furnace: Z8ES120C16SMPS1AHRI reference: 21852952716.008.10272002.34EPA 4649303

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →