Coleman / AIR-SOURCE HEAT PUMP

XH636E2S11

LX SERIES · source records, page 13

496 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity32,800–36,000BTU/h

Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 496 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17496 / 496
EER2 · BTU/Wh11–12496 / 496
HSPF2 · BTU/Wh8–8.5496 / 496
Cooling capacity · BTU/h32,800–36,000496 / 496
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200496 / 496
Heating capacity at 17°F / −8.3°C · BTU/h22,000–23,800496 / 496
Heating capacity at 5°F / −15°C · BTU/h17,600–19,800496 / 496
COP at 5°F / −15°C2–2.5496 / 496
Equipment / loop typeHP - Split System496 / 496
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)496 / 496
Compressor stagingTwo-stage496 / 496
Connected capabilityNo496 / 496

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF36B5CDS2+ furnace: Z8VT080B12SMPC1AHRI reference: 21852727116.008.10185002.34EPA 4645818
CTF48C5CFS2+ furnace: TP9C100C16MP13AHRI reference: 21852797116.008.10186002.00EPA 4646221
CTF48C5CFS2+ furnace: TM9V100C16MP12AHRI reference: 21852796716.008.10186002.00EPA 4646225
CTU48C5XFS2+TXV+ furnace: Z8VT120C20SMPC1AHRI reference: 21852796316.008.10191002.46EPA 4646229
CTF48C5CFS2+ furnace: Z8VT120C20SMPC1AHRI reference: 21852795916.008.10191002.46EPA 4646233
CTU48C5XFS2+TXV+ furnace: Z8VT100C20SMPC1AHRI reference: 21852795516.008.10192002.44EPA 4646237
CTF48C5CFS2+ furnace: Z8VT100C20SMPC1AHRI reference: 21852795116.008.10192002.44EPA 4646241
CTU48C5XFS2+TXV+ furnace: Z8VT080C16SMPC1AHRI reference: 21852794716.008.10192002.44EPA 4646245
CTF48C5CFS2+ furnace: Z8VT080C16SMPC1AHRI reference: 21852794316.008.10192002.44EPA 4646249
CTU48C5XFS2+TXV+ furnace: Z8VT100C16SMPC1AHRI reference: 21852793916.008.10192002.44EPA 4646253
CTF48C5CFS2+ furnace: Z8VT100C16SMPC1AHRI reference: 21852793516.008.10192002.44EPA 4646257
CTF36C5CDS2+JMC16C2SN1AHRI reference: 21852774916.008.50188002.40EPA 4646437
CTF36C5CDS2+JMVT16CC2N1AHRI reference: 21852774516.008.50188002.40EPA 4646441
CTF36C5CDS2+ furnace: Z8ET100C16LMPS1AHRI reference: 21852774116.008.10188002.36EPA 4646445
CTF36C5CDS2+ furnace: Z8ES120C16LMPS1AHRI reference: 21852773516.008.10185002.36EPA 4646451
CTF36C5CDS2+ furnace: Z8ES120C16SMPS1AHRI reference: 21852773116.008.10185002.36EPA 4646455
CTF36C5CDS2+JMC17C2SN1AHRI reference: 21852772716.008.50188002.38EPA 4646459
CTF36C5CDS2+JMVT17CC2N1AHRI reference: 21852772316.008.50188002.38EPA 4646463
CTF36C5CDS2+ furnace: Z9ET080C16SMPS1AHRI reference: 21852771916.008.10196002.26EPA 4646467
CTF36C5CDS2+ furnace: Z9ES080C16SMPS1AHRI reference: 21852771316.008.10196002.26EPA 4646473

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →