Coleman / AIR-SOURCE HEAT PUMP

XH636E2S11

LX SERIES

496 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity32,800–36,000BTU/h

Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 496 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17496 / 496
EER2 · BTU/Wh11–12496 / 496
HSPF2 · BTU/Wh8–8.5496 / 496
Cooling capacity · BTU/h32,800–36,000496 / 496
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200496 / 496
Heating capacity at 17°F / −8.3°C · BTU/h22,000–23,800496 / 496
Heating capacity at 5°F / −15°C · BTU/h17,600–19,800496 / 496
COP at 5°F / −15°C2–2.5496 / 496
Equipment / loop typeHP - Split System496 / 496
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)496 / 496
Compressor stagingTwo-stage496 / 496
Connected capabilityNo496 / 496

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF48C5CFS1+ furnace: Z8ET100C20LMPS1AHRI reference: 21709152317.008.10192002.44EPA 4013886
CTU48C5XFS1+TXV+ furnace: Z8ET100C20LMPS1AHRI reference: 21709152417.008.10192002.44EPA 4013887
CTF48C5CFS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21709151617.008.10192002.40EPA 4013898
CTU48C5XFS1+TXV+ furnace: Z9ET100C16SMPS1AHRI reference: 21709151717.008.10192002.40EPA 4013899
CTF48C5CFS1+JME12C2SN1AHRI reference: 21709151817.008.50190002.46EPA 4013900
CTU48C5XFS1+JME12C2SN1+TXVAHRI reference: 21709151917.008.50190002.46EPA 4013901
CTF48C5CFS1+ furnace: Z9ES080C16SMPS1AHRI reference: 21709152017.008.10189002.40EPA 4013902
CTU48C5XFS1+TXV+ furnace: Z9ES080C16SMPS1AHRI reference: 21709152217.008.10189002.40EPA 4013903
CTF48C5CFS1+JMET12CS2N1AHRI reference: 21709154717.008.50193002.44EPA 4013918
CTU48C5XFS1+JMET12CS2N1+TXVAHRI reference: 21709154817.008.50193002.44EPA 4013919
CTF48C5CFS1+JMC16C2SN1AHRI reference: 21709154917.008.50193002.46EPA 4013920
CTF48C5CFS1+ furnace: Z8ET080C16LMPS1AHRI reference: 21709155117.008.50193002.44EPA 4013921
CTU48C5XFS1+TXV+ furnace: Z8ET080C16LMPS1AHRI reference: 21709155217.008.50193002.44EPA 4013922
CTF48C5CFS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21709155317.008.10194002.44EPA 4013923
CTU48C5XFS1+JMC16C2SN1+TXVAHRI reference: 21709155017.008.50193002.46EPA 4013924
CTU48C5XFS1+TXV+ furnace: Z8ET120C20LMPS1AHRI reference: 21709155517.008.10194002.44EPA 4013925
CTF48C5CFS1+JMET16CS2N1AHRI reference: 21709157617.008.10190002.44EPA 4013940
CTU48C5XFS1+JMET16CS2N1+TXVAHRI reference: 21709157717.008.10190002.44EPA 4013941
CTF48C5CFS1+JMVT17CC2N1AHRI reference: 21709157817.008.50191002.46EPA 4013942
CTU48C5XFS1+JMVT17CC2N1+TXVAHRI reference: 21709157917.008.50191002.46EPA 4013943