Coleman / AIR-SOURCE HEAT PUMP

XH630E2S11

LX SERIES · source records, page 8

243 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.1BTU/Wh
Cooling capacity28,400–31,000BTU/h

Each efficiency range summarizes published EPA records for XH630E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 243 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17243 / 243
EER2 · BTU/Wh11–13243 / 243
HSPF2 · BTU/Wh8–8.1243 / 243
Cooling capacity · BTU/h28,400–31,000243 / 243
Heating capacity at 47°F / 8.3°C · BTU/h28,800–30,000243 / 243
Heating capacity at 17°F / −8.3°C · BTU/h18,800–20,200243 / 243
Heating capacity at 5°F / −15°C · BTU/h15,000–16,400243 / 243
COP at 5°F / −15°C2–2.4243 / 243
Equipment / loop typeHP - Split System243 / 243
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)243 / 243
Compressor stagingTwo-stage243 / 243
Connected capabilityNo243 / 243

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF36B5ADS2+ furnace: Z9ET060B12SMPS1AHRI reference: 21853037916.008.10158002.28EPA 4648487 →
CTU36B5XDS2+TXV+ furnace: Z9ES060B12SMPS1AHRI reference: 21853037316.008.10158002.28EPA 4648493 →
CTF36B5ADS2+ furnace: Z9ES060B12SMPS1AHRI reference: 21853036716.008.10158002.28EPA 4648499 →
CTU36B5XDS2+TXV+ furnace: Z9ES080B12SMPS1AHRI reference: 21853036116.008.10158002.26EPA 4648505 →
CTF36B5ADS2+ furnace: Z9ES080B12SMPS1AHRI reference: 21853035516.008.10158002.26EPA 4648511 →
CTU36B5XDS2+TXV+ furnace: Z8VT080B12SMPC1AHRI reference: 21853035116.008.10150002.38EPA 4648515 →
CTF36B5ADS2+ furnace: Z8VT080B12SMPC1AHRI reference: 21853034716.008.10150002.38EPA 4648519 →
CTU36B5XDS2+TXV+ furnace: CP9C080B12MP13AHRI reference: 21853033716.008.10156002.28EPA 4648529 →
CTU36B5XDS2+TXV+ furnace: TP9C080B12MP13AHRI reference: 21853033316.008.10156002.28EPA 4648533 →
CTU36B5XDS2+TXV+ furnace: TM9V080B12MP12AHRI reference: 21853032916.008.10156002.28EPA 4648537 →
CTF36B5ADS2+ furnace: CP9C080B12MP13AHRI reference: 21853032716.008.10156002.28EPA 4648539 →
CTF36B5ADS2+ furnace: TP9C080B12MP13AHRI reference: 21853032316.008.10156002.28EPA 4648543 →
CTF36B5ADS2+ furnace: TM9V080B12MP12AHRI reference: 21853031916.008.10156002.28EPA 4648547 →
CTU36B5XDS2+TXV+ furnace: Z8ES100B12LMPS1AHRI reference: 21853031316.008.10152002.36EPA 4648553 →
CTU36B5XDS2+TXV+ furnace: Z8ES100B12SMPS1AHRI reference: 21853030916.008.10152002.36EPA 4648557 →
CTF36B5ADS2+ furnace: Z8ES100B12LMPS1AHRI reference: 21853030316.008.10152002.36EPA 4648563 →
CTF36B5ADS2+ furnace: Z8ES100B12SMPS1AHRI reference: 21853029916.008.10152002.36EPA 4648567 →
CTU36B5XDS2+TXV+ furnace: Z9ET080B12SMPS1AHRI reference: 21853027516.008.10156002.30EPA 4648591 →
CTF36B5ADS2+ furnace: Z9ET080B12SMPS1AHRI reference: 21853027116.008.10156002.30EPA 4648595 →
CTF30B5AZS2+ furnace: Z8VT080B12SMPC1AHRI reference: 21868726316.008.10154002.00EPA 4673219 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →