Coleman / AIR-SOURCE HEAT PUMP

XH630E2S11

LX SERIES · source records, page 3

243 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.1BTU/Wh
Cooling capacity28,400–31,000BTU/h

Each efficiency range summarizes published EPA records for XH630E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 243 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17243 / 243
EER2 · BTU/Wh11–13243 / 243
HSPF2 · BTU/Wh8–8.1243 / 243
Cooling capacity · BTU/h28,400–31,000243 / 243
Heating capacity at 47°F / 8.3°C · BTU/h28,800–30,000243 / 243
Heating capacity at 17°F / −8.3°C · BTU/h18,800–20,200243 / 243
Heating capacity at 5°F / −15°C · BTU/h15,000–16,400243 / 243
COP at 5°F / −15°C2–2.4243 / 243
Equipment / loop typeHP - Split System243 / 243
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)243 / 243
Compressor stagingTwo-stage243 / 243
Connected capabilityNo243 / 243

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU36B5XDS1+TXV+ furnace: Z8ES100B12LMPS1AHRI reference: 21841829516.008.10152002.36EPA 4608569 →
CTU36B5XDS1+TXV+ furnace: Z8ES100B12SMPS1AHRI reference: 21841829116.008.10152002.36EPA 4608573 →
CTF36B5ADS1+ furnace: Z8ES100B12LMPS1AHRI reference: 21841828516.008.10152002.36EPA 4608579 →
CTF36B5ADS1+ furnace: Z8ES100B12SMPS1AHRI reference: 21841828116.008.10152002.36EPA 4608583 →
CTM36C5ADS1+ furnace: CP9C080C16MP13AHRI reference: 21841827916.008.10156002.30EPA 4608585 →
CTM36C5ADS1+ furnace: TP9C080C16MP13AHRI reference: 21841827516.008.10156002.30EPA 4608589 →
CTM36C5ADS1+ furnace: TM9V080C16MP12AHRI reference: 21841827116.008.10156002.30EPA 4608593 →
CTM36B5ADS1+ furnace: CP9C080B12MP13AHRI reference: 21841826916.008.00156002.28EPA 4608595 →
CTM36B5ADS1+ furnace: TP9C080B12MP13AHRI reference: 21841826516.008.00156002.28EPA 4608599 →
CTM36B5ADS1+ furnace: TM9V080B12MP12AHRI reference: 21841826116.008.00156002.28EPA 4608603 →
CTU36B5XDS1+TXV+ furnace: TM9E080B12MP12AHRI reference: 21841825516.008.10156002.28EPA 4608609 →
CTF36B5ADS1+ furnace: TM9E080B12MP12AHRI reference: 21841824916.008.10156002.28EPA 4608615 →
CTF36C5ADS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21841824516.008.10150002.40EPA 4608619 →
CTU36B5XDS1+TXV+ furnace: Z9ES080B12SMPS1AHRI reference: 21841821916.008.10158002.26EPA 4608645 →
CTF36B5ADS1+ furnace: Z9ES080B12SMPS1AHRI reference: 21841821316.008.10158002.26EPA 4608651 →
CTM36C5ADS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21841820116.008.10150002.40EPA 4608663 →
CTM36C5ADS1+ furnace: Z9ES080C16SMPS1AHRI reference: 21841819516.008.10154002.32EPA 4608669 →
CTM36C5ADS1+ furnace: Z9ET080C16SMPS1AHRI reference: 21841819116.008.10154002.32EPA 4608673 →
CTU36B5XDS1+TXV+ furnace: CP9C080B12MP13AHRI reference: 21841818916.008.10156002.28EPA 4608675 →
CTU36B5XDS1+TXV+ furnace: TP9C080B12MP13AHRI reference: 21841818516.008.10156002.28EPA 4608679 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →