XH630E2S11
LX SERIES
243 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH630E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 243 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 243 / 243 |
| EER2 · BTU/Wh | 11–13 | 243 / 243 |
| HSPF2 · BTU/Wh | 8–8.1 | 243 / 243 |
| Cooling capacity · BTU/h | 28,400–31,000 | 243 / 243 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 28,800–30,000 | 243 / 243 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,800–20,200 | 243 / 243 |
| Heating capacity at 5°F / −15°C · BTU/h | 15,000–16,400 | 243 / 243 |
| COP at 5°F / −15°C | 2–2.4 | 243 / 243 |
| Equipment / loop type | HP - Split System | 243 / 243 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 243 / 243 |
| Compressor staging | Two-stage | 243 / 243 |
| Connected capability | No | 243 / 243 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM36C5ADS1+ furnace: Z8ET080C16LMPS1AHRI reference: 218418323 | 17.00 | 8.10 | 15200 | 2.40 | EPA 4608541 → |
CTM36C5ADS1+ furnace: Z8ES100C16LMPS1AHRI reference: 218418311 | 17.00 | 8.10 | 15400 | 2.36 | EPA 4608553 → |
CTM36C5ADS1+ furnace: Z8ES100C16SMPS1AHRI reference: 218418307 | 17.00 | 8.10 | 15400 | 2.36 | EPA 4608557 → |
CTU36B5XDS1+TXV+ furnace: Z8ET080B12LMPS1AHRI reference: 218418209 | 17.00 | 8.10 | 15600 | 2.30 | EPA 4608655 → |
CTF36B5ADS1+ furnace: Z8ET080B12LMPS1AHRI reference: 218418205 | 17.00 | 8.10 | 15600 | 2.30 | EPA 4608659 → |
CTM36C5ADS1+ furnace: Z8ES080C16LMPS1AHRI reference: 218418043 | 17.00 | 8.10 | 15200 | 2.40 | EPA 4608821 → |
CTM36C5ADS1+ furnace: Z8ES080C16SMPS1AHRI reference: 218418039 | 17.00 | 8.10 | 15200 | 2.40 | EPA 4608825 → |
CTF36C5ADS1+ furnace: Z8ET080C16LMPS1AHRI reference: 218418035 | 17.00 | 8.10 | 15200 | 2.40 | EPA 4608829 → |
CTU36B5XDS1+TXV+ furnace: Z8ES080B12LMPS1AHRI reference: 218418029 | 17.00 | 8.10 | 15400 | 2.34 | EPA 4608835 → |
CTU36B5XDS1+TXV+ furnace: Z8ES080B12SMPS1AHRI reference: 218418025 | 17.00 | 8.10 | 15400 | 2.34 | EPA 4608839 → |
CTF36B5ADS1+ furnace: Z8ES080B12LMPS1AHRI reference: 218418019 | 17.00 | 8.10 | 15400 | 2.34 | EPA 4608845 → |
CTF36B5ADS1+ furnace: Z8ES080B12SMPS1AHRI reference: 218418015 | 17.00 | 8.10 | 15400 | 2.34 | EPA 4608849 → |
CTF36C5ADS1+ furnace: Z8ES100C16LMPS1AHRI reference: 218418009 | 17.00 | 8.10 | 15400 | 2.36 | EPA 4608855 → |
CTF36C5ADS1+ furnace: Z8ES100C16SMPS1AHRI reference: 218418005 | 17.00 | 8.10 | 15400 | 2.36 | EPA 4608859 → |
JHE36B5AD2SS1AHRI reference: 218417999 | 17.00 | 8.10 | 15400 | 2.00 | EPA 4608865 → |
JHE36C5AD2SS1AHRI reference: 218417993 | 17.00 | 8.10 | 15200 | 2.00 | EPA 4608871 → |
JHC36B5AD2SS1AHRI reference: 218417989 | 17.00 | 8.10 | 15400 | 2.00 | EPA 4608875 → |
JHC36C5AD2SS1AHRI reference: 218417985 | 17.00 | 8.10 | 15000 | 2.00 | EPA 4608879 → |
CTF36C5ADS1+ furnace: Z8ES080C16LMPS1AHRI reference: 218418461 | 17.00 | 8.10 | 15200 | 2.40 | EPA 4609549 → |
CTF36C5ADS1+ furnace: Z8ES080C16SMPS1AHRI reference: 218418457 | 17.00 | 8.10 | 15200 | 2.40 | EPA 4609553 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →