Coleman / AIR-SOURCE HEAT PUMP

XH624E2S11

LX SERIES · source records, page 2

157 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity22,800–24,200BTU/h

Each efficiency range summarizes published EPA records for XH624E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 157 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16157 / 157
EER2 · BTU/Wh11.7–12157 / 157
HSPF2 · BTU/Wh7.8–8.1157 / 157
Cooling capacity · BTU/h22,800–24,200157 / 157
Heating capacity at 47°F / 8.3°C · BTU/h22,600–24,000157 / 157
Heating capacity at 17°F / −8.3°C · BTU/h14,500–15,500157 / 157
Heating capacity at 5°F / −15°C · BTU/h11,900–12,800157 / 157
COP at 5°F / −15°C2–2.3157 / 157
Equipment / loop typeHP - Split System157 / 157
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)157 / 157
Compressor stagingTwo-stage157 / 157
Connected capabilityNo157 / 157

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF36B5ADS1+JMET12BS2N1AHRI reference: 21701947516.008.00120002.26EPA 4013436 →
CTU36B5XDS1+JMET12BS2N1+TXVAHRI reference: 21701947716.008.00120002.26EPA 4013438 →
CTF36B5ADS1+ furnace: Z9ET080B12SMPS1AHRI reference: 21701948716.008.10124002.24EPA 4013442 →
CTU36B5XDS1+TXV+ furnace: Z9ET080B12SMPS1AHRI reference: 21701948916.008.10124002.24EPA 4013444 →
CTM36B5ADS1+ furnace: Z8ES100B12SMPS1AHRI reference: 21701949316.008.10125002.26EPA 4013445 →
CTF36B5ADS1+ furnace: Z8ES080B12SMPS1AHRI reference: 21701949716.008.10124002.28EPA 4013447 →
CTU36B5XDS1+TXV+ furnace: Z8ES080B12SMPS1AHRI reference: 21701949916.008.10124002.28EPA 4013449 →
CTF36B5ADS1+ furnace: Z8ES100B12SMPS1AHRI reference: 21701950316.008.10125002.28EPA 4013452 →
CTU36B5XDS1+TXV+ furnace: Z8ES100B12SMPS1AHRI reference: 21701950516.008.10125002.28EPA 4013453 →
CTF36B5ADS1+ furnace: Z8ET080B12LMPS1AHRI reference: 21701950716.008.10124002.28EPA 4013455 →
CTU36B5XDS1+TXV+ furnace: Z8ET080B12LMPS1AHRI reference: 21701950916.008.10124002.28EPA 4013457 →
CTM36B5ADS1+ furnace: Z8ET080B12LMPS1AHRI reference: 21701951116.008.10124002.26EPA 4013458 →
CTF36B5ADS1+ furnace: Z8VT080B12SMPC1AHRI reference: 21744512716.008.10124002.28EPA 4045246 →
CTU36B5XDS1+TXV+ furnace: Z8VT080B12SMPC1AHRI reference: 21744512816.008.10124002.28EPA 4045247 →
JHE36B5AD2SS1AHRI reference: 21701944116.008.10123002.28EPA 4498121 →
CTM30B5ACS1+ furnace: Z8ES100B12LMPS1AHRI reference: 21701880816.007.80125002.10EPA 4571472 →
CTM30B5ACS1+ furnace: Z8ES100B12SMPS1AHRI reference: 21701880516.007.80125002.10EPA 4571473 →
CTM30B5ACS1+JMVT12BC2N1AHRI reference: 21701880116.007.80122002.12EPA 4571474 →
CTM30B5ACS1+JMC12B2SN1AHRI reference: 21701880016.007.80122002.12EPA 4571475 →
CTM30B5ACS1+JME12B2SN1AHRI reference: 21701879616.007.80122002.14EPA 4571476 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →