Coleman / AIR-SOURCE HEAT PUMP

XH618E2S11

LX SERIES · source records, page 2

288 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity17,000–18,300BTU/h

Each efficiency range summarizes published EPA records for XH618E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 288 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16288 / 288
EER2 · BTU/Wh12–12.5288 / 288
HSPF2 · BTU/Wh7.8–8288 / 288
Cooling capacity · BTU/h17,000–18,300288 / 288
Heating capacity at 47°F / 8.3°C · BTU/h16,100–17,000288 / 288
Heating capacity at 17°F / −8.3°C · BTU/h10,700–11,300288 / 288
Heating capacity at 5°F / −15°C · BTU/h8,700–9,100288 / 288
COP at 5°F / −15°C2.26–2.34288 / 288
Equipment / loop typeHP - Split System288 / 288
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)288 / 288
Compressor stagingSingle stage288 / 288
Connected capabilityNo288 / 288

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM30B5ACS1+JME08B2SN1AHRI reference: 21841782116.008.0089002.34EPA 4609003
CTU30B5XCS1+JME12B2SN1+TXVAHRI reference: 21841780916.008.0089002.34EPA 4609015
CTF30B5ACS1+JME12B2SN1AHRI reference: 21841780516.008.0089002.34EPA 4609019
CTU30B5XCS1+JMET12BS2N1+TXVAHRI reference: 21841780116.008.0089002.32EPA 4609023
CTF30B5ACS1+JMET12BS2N1AHRI reference: 21841779716.008.0089002.32EPA 4609027
CTM30B5ACS1+JMET08BS2N1AHRI reference: 21841779316.008.0089002.32EPA 4609031
JHC18B5AB2SS1AHRI reference: 21841742916.008.0089002.32EPA 4609223
JHC24B5AC2SS1AHRI reference: 21841738916.008.0089002.32EPA 4609255
JHE18B5AB2SS1AHRI reference: 21841717316.008.0088002.30EPA 4609405
CTU30B5XCS2+TXV+ furnace: Z8VT080B12SMPC1AHRI reference: 21853088516.008.0089002.34EPA 4648095
CTF30B5ACS2+ furnace: Z8VT080B12SMPC1AHRI reference: 21853088116.008.0089002.34EPA 4648099
CTU30B5XCS2+JMC12B2SN1+TXVAHRI reference: 21853087716.008.0089002.34EPA 4648103
CTF30B5ACS2+JMC12B2SN1AHRI reference: 21853087316.008.0089002.34EPA 4648107
CTF24B5ABS2+ furnace: Z8VT080B12SMPC1AHRI reference: 21853075516.008.0089002.34EPA 4648177
CTM30B5ACS2+JMC12B2SN1AHRI reference: 21853121316.008.0090002.32EPA 4649739
CTM30B5ACS2+ furnace: Z8VT080B12SMPC1AHRI reference: 21853120916.008.0089002.34EPA 4649743
CTM24B5ABS2+ furnace: Z8VT080B12SMPC1AHRI reference: 21853120516.008.0089002.32EPA 4649747
CTF24B5ABS2+JME12B2SN2AHRI reference: 21863843916.008.0088002.30EPA 4664236
CTF24B5ABS2+JME08B2SN2AHRI reference: 21863843516.008.0089002.32EPA 4664240
CTM30B5ACS2+JME08B2SN2AHRI reference: 21863843116.008.0089002.32EPA 4664244

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →