Coleman / AIR-SOURCE HEAT PUMP

XH560E2S11

LX SERIES

42 published source records · source checked Sep 21, 2026

SEER2 range15.2BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity54,500–56,500BTU/h

Each efficiency range summarizes published EPA records for XH560E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 42 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.242 / 42
EER2 · BTU/Wh11–11.742 / 42
HSPF2 · BTU/Wh7.8–8.142 / 42
Cooling capacity · BTU/h54,500–56,50042 / 42
Heating capacity at 47°F / 8.3°C · BTU/h55,500–57,00042 / 42
Heating capacity at 17°F / −8.3°C · BTU/h37,400–39,00042 / 42
Heating capacity at 5°F / −15°C · BTU/h29,800–32,40042 / 42
COP at 5°F / −15°C2.1–2.3842 / 42
Equipment / loop typeHP - Split System42 / 42
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)42 / 42
Compressor stagingTwo-stage42 / 42
Connected capabilityNo42 / 42

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
JHE60D5CH2SS1AHRI reference: 21442473015.207.80298002.10EPA 3627823 →
CTM60D5CJS1+JMC20D2SN1AHRI reference: 21442550015.208.10314002.34EPA 4498945 →
CTM60D5CJS1+JMVT20DC2N1AHRI reference: 21442551015.208.10314002.34EPA 4498950 →
CTF60D5CHS1+JMET18DS2N1AHRI reference: 21442934415.207.80322002.30EPA 4570779 →
CTM60D5CHS1+JME18D2SN1AHRI reference: 21442922615.207.80316002.30EPA 4570784 →
CTF60D5CHS1+JMVT20DC2N1AHRI reference: 21442889315.207.80318002.30EPA 4570799 →
JHC60C5CH2SS1AHRI reference: 21442888315.207.80316002.26EPA 4570804 →
CTM60D5CHS1+JMVT20DC2N1AHRI reference: 21442668215.207.80318002.30EPA 4570817 →
CTM60D5CJS1+JME18D2SN1AHRI reference: 21442551915.208.10316002.38EPA 4570842 →
CTM60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744502315.207.80324002.28EPA 4571128 →
CTF60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744502215.207.80324002.28EPA 4571129 →
CTU60D5XHS1+TXV+ furnace: Z8ES130D20LMPS1AHRI reference: 21678372215.207.80316002.26EPA 4572198 →
CTF60D5CHS1+ furnace: Z8ES130D20LMPS1AHRI reference: 21678370715.207.80316002.26EPA 4572203 →
CTM60C5CHS1+ furnace: Z8ES100C20LMPS1AHRI reference: 21678298315.207.80316002.26EPA 4572218 →
CTU60D5XHS1+JME18D2SN1+TXVAHRI reference: 21480912715.207.80316002.30EPA 4572258 →
CTU60D5XHS1+JMC20D2SN1+TXVAHRI reference: 21480912215.207.80318002.30EPA 4572263 →
CTU60D5XHS1+JMVT20DC2N1+TXVAHRI reference: 21480911715.207.80318002.30EPA 4572268 →
CTU60D5XHS1+JMET18DS2N1+TXVAHRI reference: 21480911215.207.80322002.30EPA 4572273 →
CTU60D5XHS1+TXV+ furnace: Z8ES130D20SMPS1AHRI reference: 21465012715.207.80316002.26EPA 4572318 →
CTF60D5CHS1+ furnace: Z8ES130D20SMPS1AHRI reference: 21460546415.207.80316002.26EPA 4572365 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →