XH548E2S11
LX SERIES · source records, page 6
370 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 370 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 370 / 370 |
| EER2 · BTU/Wh | 11–12 | 370 / 370 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 370 / 370 |
| Cooling capacity · BTU/h | 44,500–48,000 | 370 / 370 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 370 / 370 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,400 | 370 / 370 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,200 | 370 / 370 |
| COP at 5°F / −15°C | 2.1–2.42 | 370 / 370 |
| Equipment / loop type | HP - Split System | 370 / 370 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 370 / 370 |
| Compressor staging | Two-stage | 370 / 370 |
| Connected capability | No | 370 / 370 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60C5CHS1+ furnace: TM8V100C20MP12AHRI reference: 214427478 | 15.20 | 7.80 | 25800 | 2.36 | EPA 3992034 → |
CTM60C5CHS1+ furnace: TPLC100C20MP13AHRI reference: 214427488 | 15.20 | 7.80 | 25800 | 2.36 | EPA 3992044 → |
CTM60C5CHS1+ furnace: CPLC100C20MP13AHRI reference: 214427498 | 15.20 | 7.80 | 25800 | 2.36 | EPA 3992054 → |
CTF60C5CHS1+JME16C2SN1AHRI reference: 214427575 | 15.20 | 8.10 | 26000 | 2.40 | EPA 3992062 → |
CTF60C5CHS1+JMET12CS2N1AHRI reference: 214431909 | 15.20 | 7.80 | 25800 | 2.40 | EPA 3992079 → |
CTF60C5CHS1+JME12C2SN1AHRI reference: 214431994 | 15.20 | 7.80 | 25800 | 2.40 | EPA 3992085 → |
CTF60C5CHS1+JMVT16CC2N1AHRI reference: 214432026 | 15.20 | 7.80 | 26200 | 2.40 | EPA 3992088 → |
CTF60C5CHS1+ furnace: Z9ET080C16SMPS1AHRI reference: 216376883 | 15.20 | 7.80 | 26200 | 2.34 | EPA 3992218 → |
CTF60D5CHS1+ furnace: Z9ET120D20SMPS1AHRI reference: 216376912 | 15.20 | 7.80 | 26000 | 2.38 | EPA 3992223 → |
CTU60D5XHS1+TXV+ furnace: Z9ET120D20SMPS1AHRI reference: 216376941 | 15.20 | 7.80 | 26000 | 2.38 | EPA 3992234 → |
CTF60C5CHS1+ furnace: Z9ET100C16SMPS1AHRI reference: 216376994 | 15.20 | 7.80 | 26600 | 2.34 | EPA 3992247 → |
CTF60C5CHS1+ furnace: Z9ET100C20SMPS1AHRI reference: 216377024 | 15.20 | 7.80 | 26400 | 2.34 | EPA 3992253 → |
CTF60C5CHS1+ furnace: Z9ES080C20SMPS1AHRI reference: 214605234 | 15.20 | 7.80 | 25800 | 2.36 | EPA 3992261 → |
CTF60D5CHS1+ furnace: Z9ES120D20SMPS1AHRI reference: 214605254 | 15.20 | 7.80 | 25800 | 2.38 | EPA 3992265 → |
CTF60C5CHS1+ furnace: Z8ES120C16SMPS1AHRI reference: 214605599 | 15.20 | 8.10 | 26400 | 2.36 | EPA 3992271 → |
CTF60C5CHS1+ furnace: Z8ES080C20SMPS1AHRI reference: 214605604 | 15.20 | 7.80 | 26000 | 2.36 | EPA 3992277 → |
CTF60C5CHS1+ furnace: Z8ES100C16SMPS1AHRI reference: 214605664 | 15.20 | 7.80 | 26000 | 2.38 | EPA 3992281 → |
CTF60C5CHS1+ furnace: Z8ES080C16SMPS1AHRI reference: 214605669 | 15.20 | 7.80 | 26200 | 2.36 | EPA 3992287 → |
CTF60D5CHS1+ furnace: Z8ES130D20SMPS1AHRI reference: 214605739 | 15.20 | 8.10 | 26600 | 2.38 | EPA 3992290 → |
CTF60C5CHS1+ furnace: Z8ES120C20SMPS1AHRI reference: 214605779 | 15.20 | 7.80 | 26200 | 2.36 | EPA 3992295 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →