Coleman / AIR-SOURCE HEAT PUMP

XH548E2S11

LX SERIES · source records, page 2

370 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 370 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16370 / 370
EER2 · BTU/Wh11–12370 / 370
HSPF2 · BTU/Wh7.8–8.1370 / 370
Cooling capacity · BTU/h44,500–48,000370 / 370
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000370 / 370
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,400370 / 370
Heating capacity at 5°F / −15°C · BTU/h24,600–27,200370 / 370
COP at 5°F / −15°C2.1–2.42370 / 370
Equipment / loop typeHP - Split System370 / 370
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)370 / 370
Compressor stagingTwo-stage370 / 370
Connected capabilityNo370 / 370

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
JHC60D5CH2SS1AHRI reference: 21442828915.208.10264002.42EPA 3558957 →
JHE60D5CH2SS1AHRI reference: 21442829415.208.10262002.42EPA 3558961 →
CTM60C5CHS1+ furnace: TM8Y080C16MP11AHRI reference: 21442846615.207.80258002.36EPA 3559039 →
JHC48D5CG2SS1AHRI reference: 21442876015.207.80248002.26EPA 3559053 →
CTM60C5CHS1+ furnace: TM8Y120C20MP11AHRI reference: 21442914215.207.80262002.36EPA 3559093 →
CTM60C5CHS1+ furnace: TM8Y100C20MP11AHRI reference: 21442914715.207.80262002.36EPA 3559097 →
JHC60C5CH2SS1AHRI reference: 21442930915.208.10266002.38EPA 3559103 →
JSC48D5CG2SS1AHRI reference: 21483353115.207.80248002.26EPA 3560530 →
JSE48D5CG2SS1AHRI reference: 21483353615.207.80246002.26EPA 3560535 →
JHE48C5CG2SS1AHRI reference: 21442472315.207.80248002.10EPA 3627820 →
CTF60C5CHS1+ furnace: Z8ET100C16LMPS1AHRI reference: 21574299715.207.80260002.40EPA 3653150 →
CTF60C5CHS1+ furnace: Z8ET100C20LMPS1AHRI reference: 21574307015.207.80262002.38EPA 3653173 →
CTF60C5CHS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21574307515.207.80260002.40EPA 3653176 →
CTM60C5CHS1+ furnace: Z8ET100C16LMPS1AHRI reference: 21643782115.208.00260002.40EPA 3815055 →
CTM60C5CHS1+ furnace: Z9ET080C16SMPS1AHRI reference: 21643782615.207.80262002.34EPA 3815060 →
CTM60C5CHS1+ furnace: Z8ET080C16LMPS1AHRI reference: 21643783115.208.00260002.40EPA 3815065 →
CTM60C5CHS1+ furnace: Z8ET100C20LMPS1AHRI reference: 21643783615.208.10262002.40EPA 3815070 →
CTM60C5CHS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21643784115.208.00260002.40EPA 3815075 →
CTM60C5CHS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21643784615.208.00258002.38EPA 3815080 →
CTM60C5CHS1+ furnace: Z9ET100C20SMPS1AHRI reference: 21643785115.208.00264002.36EPA 3815085 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →