XH548E2S11
LX SERIES · source records, page 15
370 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 370 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 370 / 370 |
| EER2 · BTU/Wh | 11–12 | 370 / 370 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 370 / 370 |
| Cooling capacity · BTU/h | 44,500–48,000 | 370 / 370 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 370 / 370 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,400 | 370 / 370 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,200 | 370 / 370 |
| COP at 5°F / −15°C | 2.1–2.42 | 370 / 370 |
| Equipment / loop type | HP - Split System | 370 / 370 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 370 / 370 |
| Compressor staging | Two-stage | 370 / 370 |
| Connected capability | No | 370 / 370 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60C5CGS2+ furnace: Z8ES120C16SMPS1AHRI reference: 218517650 | 15.20 | 7.80 | 25800 | 2.26 | EPA 4641801 → |
CTM60C5CGS2+ furnace: Z8ES080C20LMPS1AHRI reference: 218517646 | 15.20 | 7.80 | 25800 | 2.26 | EPA 4641805 → |
CTM60C5CGS2+ furnace: Z8ES080C20SMPS1AHRI reference: 218517642 | 15.20 | 7.80 | 25800 | 2.26 | EPA 4641809 → |
CTM60C5CGS2+ furnace: Z8ES100C20LMPS1AHRI reference: 218517638 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4641813 → |
CTM60C5CGS2+ furnace: Z8ES100C20SMPS1AHRI reference: 218517634 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4641817 → |
CTM60C5CGS2+JMC16C2SN1AHRI reference: 218517626 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4641821 → |
CTM60C5CGS2+JMVT16CC2N1AHRI reference: 218517622 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4641825 → |
CTM60C5CGS2+JMVT17CC2N1AHRI reference: 218517614 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4641829 → |
CTM60C5CGS2+ furnace: Z8VT100C20SMPC1AHRI reference: 218517606 | 15.20 | 7.80 | 25800 | 2.26 | EPA 4641833 → |
CTM60C5CGS2+ furnace: Z8VT120C20SMPC1AHRI reference: 218517598 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4641837 → |
CTF60D5CHS2+ furnace: Z9ET120D20SMPS1AHRI reference: 218517590 | 15.20 | 7.80 | 26000 | 2.38 | EPA 4641845 → |
CTF60D5CHS2+ furnace: Z8ES130D20LMPS1AHRI reference: 218517578 | 15.20 | 8.10 | 26600 | 2.38 | EPA 4641857 → |
CTF60D5CHS2+ furnace: Z8ES130D20SMPS1AHRI reference: 218517574 | 15.20 | 8.10 | 26600 | 2.38 | EPA 4641861 → |
CTF60D5CHS2+JMC20D2SN1AHRI reference: 218517566 | 15.20 | 8.10 | 26200 | 2.42 | EPA 4641869 → |
CTF60D5CHS2+JMVT20DC2N1AHRI reference: 218517558 | 15.20 | 8.10 | 26200 | 2.42 | EPA 4641877 → |
CTF60D5CHS2+ furnace: CP9C120D20MP13AHRI reference: 218517546 | 15.20 | 7.80 | 26800 | 2.34 | EPA 4641889 → |
CTF60D5CHS2+ furnace: TP9C120D20MP13AHRI reference: 218517542 | 15.20 | 7.80 | 26800 | 2.34 | EPA 4641893 → |
CTF60D5CHS2+ furnace: TM9V120D20MP12AHRI reference: 218517538 | 15.20 | 7.80 | 26800 | 2.34 | EPA 4641897 → |
CTF60D5CHS2+ furnace: Z9ES120D20SMPS1AHRI reference: 218517530 | 15.20 | 7.80 | 25800 | 2.38 | EPA 4641905 → |
CTF60D5CGS2+JMC20D2SN1AHRI reference: 218517514 | 15.20 | 7.80 | 24600 | 2.28 | EPA 4641913 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.