Coleman / AIR-SOURCE HEAT PUMP

XH536E2S11

LX SERIES · source records, page 7

275 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,400–35,000BTU/h

Each efficiency range summarizes published EPA records for XH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 275 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16275 / 275
EER2 · BTU/Wh10–12275 / 275
HSPF2 · BTU/Wh7.8–8.1275 / 275
Cooling capacity · BTU/h32,400–35,000275 / 275
Heating capacity at 47°F / 8.3°C · BTU/h30,600–32,800275 / 275
Heating capacity at 17°F / −8.3°C · BTU/h20,400–22,000275 / 275
Heating capacity at 5°F / −15°C · BTU/h17,000–18,400275 / 275
COP at 5°F / −15°C2–2.44275 / 275
Equipment / loop typeHP - Split System275 / 275
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)275 / 275
Compressor stagingTwo-stage275 / 275
Connected capabilityNo275 / 275

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36C5CDS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21460557915.208.10177002.42EPA 4046974 →
CTU48C5XFS1+TXV+ furnace: Z8ES080C20SMPS1AHRI reference: 21480867315.208.10176002.00EPA 4046979 →
CTF36C5CDS1+ furnace: Z8ES120C16SMPS1AHRI reference: 21460560915.208.10173002.00EPA 4046984 →
CTF36C5CDS1+ furnace: Z8ES100C16SMPS1AHRI reference: 21460569915.208.10179002.00EPA 4046989 →
CTU48C5XFS1+TXV+ furnace: Z9ES080C20SMPS1AHRI reference: 21480869815.208.10178002.00EPA 4046992 →
CTF36C5CDS1+ furnace: Z8ET100C16LMPS1AHRI reference: 21574303915.208.10180002.40EPA 4046998 →
CTM36C5CDS1+ furnace: Z8ES120C20SMPS1AHRI reference: 21460583915.208.10180002.36EPA 4046999 →
CTF36C5CDS1+ furnace: Z8ES120C20SMPS1AHRI reference: 21460571415.208.10176002.00EPA 4047003 →
CTF48C5CFS1+ furnace: Z8ES080C20SMPS1AHRI reference: 21460574415.208.10176002.00EPA 4047008 →
CTM48C5CFS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21678201215.208.10177002.40EPA 4047017 →
CTF36C5CDS1+ furnace: Z8ES120C20LMPS1AHRI reference: 21678210715.208.10176002.00EPA 4047021 →
CTF36C5CDS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21678215215.208.10173002.00EPA 4047026 →
CTF36C5CDS1+ furnace: Z8ES080C20SMPS1AHRI reference: 21460588915.208.10179002.00EPA 4047031 →
CTF36C5CDS1+ furnace: Z8ES080C16LMPS1AHRI reference: 21678347015.208.10171002.00EPA 4047034 →
CTF48C5CFS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21678410915.208.10174002.00EPA 4047043 →
CTU48C5XFS1+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 21678412315.208.10174002.00EPA 4047049 →
CTM36C5CDS1+ furnace: Z8ES080C20SMPS1AHRI reference: 21460589415.208.10179002.40EPA 4047058 →
CTM36C5CDS1+ furnace: Z8ES080C16LMPS1AHRI reference: 21678490115.208.10174002.42EPA 4047078 →
CTM36C5CDS1+ furnace: Z8ES120C20LMPS1AHRI reference: 21678663515.208.10180002.36EPA 4047103 →
CTM48C5CFS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21643779615.208.10178002.36EPA 4047107 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →