XH524E2S11
LX SERIES · source records, page 3
55 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH524E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 55 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 55 / 55 |
| EER2 · BTU/Wh | 11.7–12 | 55 / 55 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 55 / 55 |
| Cooling capacity · BTU/h | 23,000–24,000 | 55 / 55 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,200–23,600 | 55 / 55 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,200–15,400 | 55 / 55 |
| Heating capacity at 5°F / −15°C · BTU/h | 11,200–12,700 | 55 / 55 |
| COP at 5°F / −15°C | 2–2.28 | 55 / 55 |
| Equipment / loop type | HP - Split System | 55 / 55 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 55 / 55 |
| Compressor staging | Two-stage | 55 / 55 |
| Connected capability | No | 55 / 55 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM30B5ACS2+ furnace: Z9ES080B12SMPS1AHRI reference: 218524902 | 15.20 | 8.00 | 12300 | 2.22 | EPA 4645103 → |
CTM30B5ACS2+ furnace: Z8ET080B12LMPS1AHRI reference: 218524898 | 15.20 | 8.10 | 12400 | 2.26 | EPA 4645107 → |
CTM30B5ACS2+ furnace: Z9ET060B12SMPS1AHRI reference: 218524894 | 15.20 | 8.00 | 12700 | 2.22 | EPA 4645111 → |
CTM30B5ACS2+JMC12B2SN1AHRI reference: 218524890 | 15.20 | 8.10 | 12300 | 2.28 | EPA 4645115 → |
CTM30B5ACS2+JMVT12BC2N1AHRI reference: 218524886 | 15.20 | 8.10 | 12300 | 2.28 | EPA 4645119 → |
CTU30B5XCS2+TXV+ furnace: Z9ET080B12SMPS1AHRI reference: 218524878 | 15.20 | 8.10 | 12500 | 2.24 | EPA 4645127 → |
CTF30B5ACS2+ furnace: Z9ET080B12SMPS1AHRI reference: 218524874 | 15.20 | 8.10 | 12500 | 2.24 | EPA 4645131 → |
CTU30B5XCS2+TXV+ furnace: Z9ET060B12SMPS1AHRI reference: 218524870 | 15.20 | 8.10 | 12600 | 2.22 | EPA 4645135 → |
CTF30B5ACS2+ furnace: Z9ET060B12SMPS1AHRI reference: 218524866 | 15.20 | 8.10 | 12600 | 2.22 | EPA 4645139 → |
CTU30B5XCS2+JMVT12BC2N1+TXVAHRI reference: 218524862 | 15.20 | 7.80 | 12300 | 2.18 | EPA 4645143 → |
CTF30B5ACS2+JMVT12BC2N1AHRI reference: 218524858 | 15.20 | 7.80 | 12300 | 2.18 | EPA 4645147 → |
CTU30B5XCS2+JMC12B2SN1+TXVAHRI reference: 218524790 | 15.20 | 7.80 | 11700 | 2.06 | EPA 4645151 → |
CTF30B5ACS2+JMC12B2SN1AHRI reference: 218524786 | 15.20 | 7.80 | 11700 | 2.06 | EPA 4645155 → |
CTM30B5ACS2+JME08B2SN2AHRI reference: 218637901 | 15.20 | 8.00 | 12100 | 2.24 | EPA 4663890 → |
CTM30B5ACS2+JME12B2SN2AHRI reference: 218637889 | 15.20 | 8.00 | 12200 | 2.26 | EPA 4663894 → |